Telemark Rechenzentrum Menden
Telemark Rechenzentrum Menden is an operational data center operated by Telemark Telekommunikationsgesellschaft Mark mbH in Menden, Germany. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Telemark Telekommunikationsgesellschaft Mark mbH |
| Networks | 1 networks PeeringDB. |
| Address | Am Papenbusch 8-10 |
| Coordinates | 51.44055, 7.76883 |
| Website | telemark.de/it-systempartner/rechenzentrum |
Power and grid
| Nearest high-voltage substation | Station Menden, 110 kV, 1.4 km away (Westnetz) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Bixterheide, 220 kV, 4.7 km away |
| HV substations within 10 km | 11 |
| Power plants within 50 km | 7.2 GW in 51 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38 °C (2001 to 2025) |
| Cooling degree days | 106 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.87 kWh per m² per day |
| Wind at 50 m | 6.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Telemark Rechenzentrum Menden to the power grid?
The nearest high-voltage substation in OpenStreetMap is Station Menden (110 kV), about 1.4 km away.
How clean is the power for Telemark Rechenzentrum Menden?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Telemark Rechenzentrum Menden?
Telemark Telekommunikationsgesellschaft Mark mbH.
Data centers near Menden
- DOKOM21 RZ Hörde 19.5 km
- euNetworks Colocation Dortmund 21.4 km · 0.8 MW
- Stadtwerke Lüdenscheid GmbH (ENERVIE-Gruppe) 25.5 km · 4.9 MW
- Telemark Rechenzentrum Lüdenscheid 25.6 km
- DOKOM21 RZ Huckarde 26.4 km · 2.7 MW
- Data center in Querenburg 34.0 km · 2 MW
- TMR Telehouse Bochum 38.4 km
- GFR DataCenter Bochum 40.1 km
More Telemark Telekommunikationsgesellschaft Mark mbH data centers
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.