DOKOM21 RZ Huckarde
DOKOM21 RZ Huckarde is an operational data center operated by DOKOM Gesellschaft für Telekommunikation mbH in Dortmund, Germany. Our footprint estimate of its power is about 2.7 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | DOKOM Gesellschaft für Telekommunikation mbH |
| Facility power | 2.7 MW (range 1.3 MW to 4.3 MW) Estimate from building footprint, low confidence. Footprint estimate: about 2,219 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,200 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 2 networks, 1 internet exchanges PeeringDB. |
| Also known as | RZ5 Dortmund-Huckarde |
| Address | Fallgatter 11 |
| Coordinates | 51.53536, 7.41890 |
| Website | dokom21.de/de/Geschaeftskunden/rechenzentrum/losungen/serverraum--rack.htm |
Power and grid
| Nearest high-voltage substation | Hafen, 110 kV, 1 km away (Westnetz) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Station Ratsbusch, 220 kV, 5.6 km away |
| HV substations within 10 km | 27 |
| Power plants within 50 km | 10.0 GW in 56 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.2 °C (2001 to 2025) |
| Cooling degree days | 116 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.96 kWh per m² per day |
| Wind at 50 m | 6.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does DOKOM21 RZ Huckarde use?
We estimate the facility power at about 2.7 MW. Estimate from building footprint, low confidence.
How close is DOKOM21 RZ Huckarde to the power grid?
The nearest high-voltage substation in OpenStreetMap is Hafen (110 kV), about 1 km away.
How clean is the power for DOKOM21 RZ Huckarde?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates DOKOM21 RZ Huckarde?
DOKOM Gesellschaft für Telekommunikation mbH.
Data centers near Dortmund
- euNetworks Colocation Dortmund 5.0 km · 0.8 MW
- DOKOM21 RZ Hörde 7.5 km
- Data center in Querenburg 13.6 km · 2 MW
- GFR DataCenter Herne 14.6 km
- TMR Telehouse Bochum 14.7 km
- GFR DataCenter Bochum 17.0 km
- GELSEN-NET DC Resse 21.5 km
- Telemark Rechenzentrum Menden 26.4 km
More DOKOM Gesellschaft für Telekommunikation mbH data centers
- DOKOM21 RZ Hörde Germany
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.