Data Center Directory

DOKOM21 RZ Huckarde

DOKOM21 RZ Huckarde is an operational data center operated by DOKOM Gesellschaft für Telekommunikation mbH in Dortmund, Germany. Our footprint estimate of its power is about 2.7 MW.

Key facts

StatusOperational
OperatorDOKOM Gesellschaft für Telekommunikation mbH
Facility power2.7 MW (range 1.3 MW to 4.3 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 2,219 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 1,200 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks2 networks, 1 internet exchanges
PeeringDB.
Also known asRZ5 Dortmund-Huckarde
AddressFallgatter 11
Coordinates51.53536, 7.41890
Websitedokom21.de/de/Geschaeftskunden/rechenzentrum/losungen/serverraum--rack.htm

Power and grid

Nearest high-voltage substationHafen, 110 kV, 1 km away (Westnetz)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationStation Ratsbusch, 220 kV, 5.6 km away
HV substations within 10 km27
Power plants within 50 km10.0 GW in 56 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity334 g CO₂ per kWh (Germany, 2025)
Average of all power made in the area. Ember.
Grid power mixwind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5%
Industrial power priceEUR 0.146 per kWh (Germany, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature9.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.2 °C (2001 to 2025)
Cooling degree days116 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.96 kWh per m² per day
Wind at 50 m6.7 m/s average
Water stress todayMedium - High (20-40%) (Germany)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does DOKOM21 RZ Huckarde use?

We estimate the facility power at about 2.7 MW. Estimate from building footprint, low confidence.

How close is DOKOM21 RZ Huckarde to the power grid?

The nearest high-voltage substation in OpenStreetMap is Hafen (110 kV), about 1 km away.

How clean is the power for DOKOM21 RZ Huckarde?

The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.

Who operates DOKOM21 RZ Huckarde?

DOKOM Gesellschaft für Telekommunikation mbH.

Data centers near Dortmund

More DOKOM Gesellschaft für Telekommunikation mbH data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.