PTOR1

PTOR1 is an operational data center operated by 1547 Critical Systems Realty in Portland, United States. Our footprint estimate of its power is about 12 MW.

Key facts

StatusOperational
Operator1547 Critical Systems Realty
Facility power12 MW (range 5.8 MW to 19 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 4,826 m² building outline x 2 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 5,100 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks70 networks, 2 internet exchanges
PeeringDB.
Also known asPittock Block · The Pittock Internet Exchange
Address921 SW Washington St
Coordinates45.52137, -122.68079
Website1547realty.com

Power and grid

UtilityPortland General Electric Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPGE
Nearest gas pipelineNorthwest Pipeline, interstate pipeline, 12.5 km away
US Energy Information Administration pipeline map. Straight-line distance.
Grid carbon intensity200 g CO₂ per kWh (Oregon, 2025)
Average of all power made in the area. Ember.
Grid power mixhydro 44.6%, gas 33.9%, wind 14.5%, solar 5.2%, bioenergy 1.6%. Clean power: 66.2%
Industrial power priceUSD 0.087 per kWh (Oregon, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature10.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature40.6 °C (2001 to 2025)
Cooling degree days179 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.67 kWh per m² per day
Wind at 50 m4 m/s average
Water stress todayLow - Medium (10-20%) (Oregon)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does PTOR1 use?

We estimate the facility power at about 12 MW. Estimate from building footprint, low confidence.

How clean is the power for PTOR1?

The grid in Oregon emits about 200 g CO₂ per kWh (2025). Largest sources: hydro 44.6%, gas 33.9%, wind 14.5%.

Who operates PTOR1?

1547 Critical Systems Realty.