H5 Data Centers Portland (OR01)
H5 Data Centers Portland (OR01) is an operational data center operated by H5 Data Centers in Portland, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | H5 Data Centers |
| Networks | 3 networks, 1 internet exchanges PeeringDB. |
| Also known as | H5 DC - Portland |
| Address | 1233 NW 12th Avenue, Suite 201 |
| Coordinates | 45.53185, -122.68396 |
| Website | h5datacenters.com |
Power and grid
| Nearest high-voltage substation | Albina Substation, 115 kV, 900 m away (Pacific Power) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Saint Johns Substation, 230 kV, 11.1 km away |
| HV substations within 10 km | 29 |
| Utility | Portland General Electric Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PGE |
| Nearest gas pipeline | Northwest Pipeline, interstate pipeline, 11.4 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 1.1 GW in 55 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 200 g CO₂ per kWh (Oregon, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 44.6%, gas 33.9%, wind 14.5%, solar 5.2%, bioenergy 1.6%. Clean power: 66.2% |
| Industrial power price | USD 0.087 per kWh (Oregon, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 10.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.6 °C (2001 to 2025) |
| Cooling degree days | 179 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.67 kWh per m² per day |
| Wind at 50 m | 4 m/s average |
| Water stress today | Low - Medium (10-20%) (Oregon) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is H5 Data Centers Portland (OR01) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Albina Substation (115 kV), about 900 m away. The local utility is Portland General Electric Co, in the PGE balancing area.
How clean is the power for H5 Data Centers Portland (OR01)?
The grid in Oregon emits about 200 g CO₂ per kWh (2025). Largest sources: hydro 44.6%, gas 33.9%, wind 14.5%.
Who operates H5 Data Centers Portland (OR01)?
H5 Data Centers.
Data centers near Portland
- Lumen Portland 80 m
- Opus Interactive Portland (PDX01) 978 m
- PTOR1 1.2 km · 12 MW
- Digital Fortress (PTL) 1.2 km
- LightPoint Corporation 1.3 km
- Corepacket PDX-1 1.3 km
- Digital Fortress (PTL2) 9.5 km
- BVTNORXB - Beaverton Central Office 11.0 km
More H5 Data Centers data centers
- H5 Data Centers Ashburn United States
- H5 Data Centers Omaha United States
- H5 Data Centers Quincy United States
- H5 Data Centers Virginia (4030) United States
- H5 Data Centers Quincy 2/3 United States
- H5 Data Centers Minneapolis United States
- H5 Data Centers Phoenix United States
- H5 Data Centers San Antonio United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.