H5 Data Centers San Antonio
H5 Data Centers San Antonio is an operational data center operated by H5 Data Centers in San Antonio, United States. Our footprint estimate of its power is about 3.5 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | H5 Data Centers |
| Facility power | 3.5 MW (range 1.8 MW to 5.6 MW) Estimate from building footprint, low confidence. Footprint estimate: about 2,927 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 20 networks, 1 internet exchanges PeeringDB. |
| Address | 100 Taylor St |
| Coordinates | 29.42937, -98.48679 |
| Website | h5datacenters.com/san-antonio-data-center.html |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 138 kV, 800 m away (CPS Energy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 345 kV, 18.4 km away |
| HV substations within 10 km | 26 |
| Utility | City Of San Antonio (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | ERCO |
| Nearest gas pipeline | El Paso Texas Pipeline Co, intrastate pipeline, 10.3 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 6.5 GW in 28 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 20.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 44.5 °C (2001 to 2025) |
| Cooling degree days | 1,804 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.84 kWh per m² per day |
| Wind at 50 m | 6.1 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does H5 Data Centers San Antonio use?
We estimate the facility power at about 3.5 MW. Estimate from building footprint, low confidence.
How close is H5 Data Centers San Antonio to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 800 m away. The local utility is City Of San Antonio, in the ERCO balancing area.
How clean is the power for H5 Data Centers San Antonio?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates H5 Data Centers San Antonio?
H5 Data Centers.
Data centers near San Antonio
- Foremost San Antonio 50 m
- Microsoft SAT40 967 m · 106 MW
- Lumen San Antonio 2 2.2 km · 1.3 MW
- Lumen San Antonio 1 10.6 km
- Data center in Leon Valley 14.9 km · 16 MW
- Texas Cryptologic Center 15.0 km · 4.7 MW
- Data center in Leon Valley 15.3 km · 7.2 MW
- QTS San Antonio 16.2 km · 15 MW
More H5 Data Centers data centers
- H5 Data Centers Ashburn United States
- H5 Data Centers Omaha United States
- H5 Data Centers Quincy United States
- H5 Data Centers Virginia (4030) United States
- H5 Data Centers Quincy 2/3 United States
- H5 Data Centers Minneapolis United States
- H5 Data Centers Phoenix United States
- H5 Data Centers Albuquerque United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.