STACK Infrastructre - ZUR01A
STACK Infrastructre - ZUR01A is an operational data center operated by STACK Infrastructre in Jestetten, Germany. Our footprint estimate of its power is about 16 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | STACK Infrastructre |
| Facility power | 16 MW (range 8.1 MW to 26 MW) Estimate from building footprint, low confidence. Footprint estimate: about 13,522 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 6,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 47.60096, 8.54166 |
| Website | stackinfra.com/locations/zurich |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 110 kV, 200 m away (Axpo;EKS;EKZ) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 220 kV, 5.9 km away |
| HV substations within 10 km | 5 |
| Power plants within 50 km | 3.5 GW in 50 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 33.5 °C (2001 to 2025) |
| Cooling degree days | 117 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.4 kWh per m² per day |
| Wind at 50 m | 4.3 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does STACK Infrastructre - ZUR01A use?
We estimate the facility power at about 16 MW. Estimate from building footprint, low confidence.
How close is STACK Infrastructre - ZUR01A to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (110 kV), about 200 m away.
How clean is the power for STACK Infrastructre - ZUR01A?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates STACK Infrastructre - ZUR01A?
STACK Infrastructre.
Data centers near Jestetten
- STACK infrastructure ZUR01 81 m
- STACK Infrastructure data center in Beringen 10.7 km · 6.4 MW
- Ebnat Schaffhausen 13.9 km
- Green Datacenter ZRH2 (fka: Green Dielsdorf) 14.6 km · 5.8 MW
- NTT Zurich 1 Data Center (ZRH1) 16.8 km · 6.2 MW
- AXA Data Center 17.4 km
- DataCenter Winterthur 17.5 km
- NorthC Winterthur (Zürich) 17.7 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.