NTT Zurich 1 Data Center (ZRH1)
NTT Zurich 1 Data Center (ZRH1) is an operational data center operated by NTT Global Data Centers in Rümlang, Switzerland. Our footprint estimate of its power is about 6.2 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | NTT Global Data Centers |
| Facility power | 6.2 MW (range 3.1 MW to 10 MW) Estimate from building footprint, low confidence. Footprint estimate: about 5,189 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,600 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 63 networks, 7 internet exchanges PeeringDB. |
| Also known as | NTT Zurich 1 Data Center |
| Address | Hofwisenstrasse 54-56 |
| Coordinates | 47.45009, 8.53989 |
| Website | datacenter.hello.global.ntt/en/location/switzerland/zurich-1-data-center |
Power and grid
| Nearest high-voltage substation | Unterwerk Rümlang, 110 kV, 1.4 km away (Axpo/EKZ) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Quartierunterwerk Seebach, 220 kV, 3.2 km away |
| HV substations within 10 km | 30 |
| Power plants within 50 km | 3.6 GW in 52 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 39 g CO₂ per kWh (Switzerland, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 52.3%, nuclear 29.9%, solar 12.1%, oil and other fossil 1.9%, bioenergy 1.6%. Clean power: 97.7% |
Climate and water
| Average temperature | 9.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 33.5 °C (2001 to 2025) |
| Cooling degree days | 117 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.4 kWh per m² per day |
| Wind at 50 m | 4.3 m/s average |
| Water stress today | Low (<10%) (Switzerland) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does NTT Zurich 1 Data Center (ZRH1) use?
We estimate the facility power at about 6.2 MW. Estimate from building footprint, low confidence.
How close is NTT Zurich 1 Data Center (ZRH1) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Unterwerk Rümlang (110 kV), about 1.4 km away.
How clean is the power for NTT Zurich 1 Data Center (ZRH1)?
The grid in Switzerland emits about 39 g CO₂ per kWh (2025). Largest sources: hydro 52.3%, nuclear 29.9%, solar 12.1%.
Who operates NTT Zurich 1 Data Center (ZRH1)?
NTT Global Data Centers.
Data centers near Rümlang
- Digital Realty Zurich ZUR1 2.3 km · 55 MW
- Green Datacenter ZRH4 (fka: Green Glattbrugg) 2.4 km
- GLB2 2.4 km · 6.1 MW
- OIZ 4.3 km
- EHOST 6.2 km
- SBDC Zürich 6.4 km
- Green Datacenter ZRH2 (fka: Green Dielsdorf) 6.8 km · 5.8 MW
- Data center in Zürich 7.0 km · 5.9 MW
More NTT Global Data Centers data centers
- NTT VA10 United States
- NTT Frankfurt 2 Data Center (FRA2) Germany
- NTT PH1 Datacenter United States
- NTT Japan
- NTTData Data Center United States
- NTT Hemel Hempstead 4 Data Center (HH4) United Kingdom
- NTT Berlin 1 Data Center (BER1) Germany
- NTT London 1 United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.