Green Datacenter ZRH2 (fka: Green Dielsdorf)
Green Datacenter ZRH2 (fka: Green Dielsdorf) is a data center under construction operated by Green Datacenter in Dielsdorf, Switzerland. Our footprint estimate of its power is about 5.8 MW.
Key facts
| Status | Under construction |
|---|---|
| Operator | Green Datacenter |
| Facility power | 5.8 MW (range 2.9 MW to 9.2 MW) Estimate from building footprint, low confidence. Footprint estimate: about 4,800 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 10 networks, 2 internet exchanges PeeringDB. |
| Also known as | Green Metro-Campus Zürich Datacenter M |
| Address | Niederhaslistrasse 6a/b/c |
| Coordinates | 47.48111, 8.46250 |
| Website | greendatacenter.ch |
Power and grid
| Nearest high-voltage substation | Unterwerk Dielsdorf, 110 kV, 100 m away (EKZ) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unterwerk Regensdorf, 220 kV, 3.2 km away |
| HV substations within 10 km | 14 |
| Power plants within 50 km | 6.2 GW in 58 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 39 g CO₂ per kWh (Switzerland, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 52.3%, nuclear 29.9%, solar 12.1%, oil and other fossil 1.9%, bioenergy 1.6%. Clean power: 97.7% |
Climate and water
| Average temperature | 9.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 33.5 °C (2001 to 2025) |
| Cooling degree days | 117 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.4 kWh per m² per day |
| Wind at 50 m | 4.3 m/s average |
| Water stress today | Low (<10%) (Switzerland) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Green Datacenter ZRH2 (fka: Green Dielsdorf) use?
We estimate the facility power at about 5.8 MW. Estimate from building footprint, low confidence.
How close is Green Datacenter ZRH2 (fka: Green Dielsdorf) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Unterwerk Dielsdorf (110 kV), about 100 m away.
How clean is the power for Green Datacenter ZRH2 (fka: Green Dielsdorf)?
The grid in Switzerland emits about 39 g CO₂ per kWh (2025). Largest sources: hydro 52.3%, nuclear 29.9%, solar 12.1%.
Who operates Green Datacenter ZRH2 (fka: Green Dielsdorf)?
Green Datacenter.
Data centers near Dielsdorf
- NTT Zurich 1 Data Center (ZRH1) 6.8 km · 6.2 MW
- Equinix ZH5 - Zurich, South 8.4 km · 7.2 MW
- FSIT Dietikon CH-DIE001 8.5 km
- Green Datacenter ZRH3 (fka: Green Schlieren) 8.8 km · 0.8 MW
- Digital Realty Zurich ZUR1 8.9 km · 55 MW
- Green Datacenter ZRH4 (fka: Green Glattbrugg) 9.0 km
- GLB2 9.0 km · 6.1 MW
- Templus DC Zurich ZRH01 9.7 km
More Green Datacenter data centers
- Green Datacenter ZRH1 (fka: Green Lupfig) Switzerland
- Green Datacenter ZRH3 (fka: Green Schlieren) Switzerland
- Green Datacenter ZRH4 (fka: Green Glattbrugg) Switzerland
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.