Equinix ZH5 - Zurich, South
Equinix ZH5 - Zurich, South is an operational data center operated by Equinix in Zurich, Switzerland. Our footprint estimate of its power is about 7.2 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 7.2 MW (range 3.6 MW to 12 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,016 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 53 networks, 4 internet exchanges PeeringDB. |
| Also known as | Equinix ZRH5 |
| Address | Allmendstrasse 13, Oberengstringen |
| Coordinates | 47.40567, 8.46174 |
| Website | equinix.com/locations/switzerland-colocation/zurich-data-centers/zh5 |
Power and grid
| Nearest high-voltage substation | Unterwerk Schlieren, 110 kV, 2.2 km away (Axpo/EKZ) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unterwerk Regensdorf, 220 kV, 5.3 km away |
| HV substations within 10 km | 28 |
| Power plants within 50 km | 6.1 GW in 57 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 39 g CO₂ per kWh (Switzerland, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 52.3%, nuclear 29.9%, solar 12.1%, oil and other fossil 1.9%, bioenergy 1.6%. Clean power: 97.7% |
Climate and water
| Average temperature | 9.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 33.5 °C (2001 to 2025) |
| Cooling degree days | 117 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.4 kWh per m² per day |
| Wind at 50 m | 4.3 m/s average |
| Water stress today | Low (<10%) (Switzerland) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix ZH5 - Zurich, South use?
We estimate the facility power at about 7.2 MW. Estimate from building footprint, low confidence.
How close is Equinix ZH5 - Zurich, South to the power grid?
The nearest high-voltage substation in OpenStreetMap is Unterwerk Schlieren (110 kV), about 2.2 km away.
How clean is the power for Equinix ZH5 - Zurich, South?
The grid in Switzerland emits about 39 g CO₂ per kWh (2025). Largest sources: hydro 52.3%, nuclear 29.9%, solar 12.1%.
Who operates Equinix ZH5 - Zurich, South?
Equinix.
Data centers near Zurich
- Templus DC Zurich ZRH01 1.6 km
- Green Datacenter ZRH3 (fka: Green Schlieren) 1.8 km · 0.8 MW
- Data center in Zürich 3.2 km · 5.9 MW
- colozueri.ch Zurich 3.6 km
- Rechenzentrum Albis 4.0 km · 4.6 MW
- Equinix ZH2 - Zurich 4.8 km
- FSIT Dietikon CH-DIE001 5.2 km
- aspectra Zürich 6.4 km
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.