Green Datacenter ZRH1 (fka: Green Lupfig)
Green Datacenter ZRH1 (fka: Green Lupfig) is an operational data center operated by Green Datacenter in Lupfig, Switzerland. Our footprint estimate of its power is about 7.8 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Green Datacenter |
| Facility power | 7.8 MW (range 3.9 MW to 12 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,500 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,300 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 26 networks, 4 internet exchanges PeeringDB. |
| Address | Industriestr. 33 |
| Coordinates | 47.44650, 8.21104 |
| Website | greendatacenter.ch |
Power and grid
| Nearest high-voltage substation | Unterwerk Lupfig, 110 kV, 600 m away (Axpo;AEW) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 220 kV, 1.2 km away |
| HV substations within 10 km | 12 |
| Power plants within 50 km | 6.2 GW in 58 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 39 g CO₂ per kWh (Switzerland, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 52.3%, nuclear 29.9%, solar 12.1%, oil and other fossil 1.9%, bioenergy 1.6%. Clean power: 97.7% |
Climate and water
| Average temperature | 9.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 32.9 °C (2001 to 2025) |
| Cooling degree days | 110 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.4 kWh per m² per day |
| Wind at 50 m | 4.5 m/s average |
| Water stress today | Low (<10%) (Aargau) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Green Datacenter ZRH1 (fka: Green Lupfig) use?
We estimate the facility power at about 7.8 MW. Estimate from building footprint, low confidence.
How close is Green Datacenter ZRH1 (fka: Green Lupfig) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Unterwerk Lupfig (110 kV), about 600 m away.
How clean is the power for Green Datacenter ZRH1 (fka: Green Lupfig)?
The grid in Switzerland emits about 39 g CO₂ per kWh (2025). Largest sources: hydro 52.3%, nuclear 29.9%, solar 12.1%.
Who operates Green Datacenter ZRH1 (fka: Green Lupfig)?
Green Datacenter.
Data centers near Lupfig
- FSIT Dietikon CH-DIE001 14.3 km
- Green Datacenter ZRH3 (fka: Green Schlieren) 17.7 km · 0.8 MW
- Green Datacenter ZRH2 (fka: Green Dielsdorf) 19.3 km · 5.8 MW
- Equinix ZH5 - Zurich, South 19.4 km · 7.2 MW
- Templus DC Zurich ZRH01 20.6 km
- Data center in Zürich 22.5 km · 5.9 MW
- colozueri.ch Zurich 22.5 km
- Rechenzentrum Albis 22.7 km · 4.6 MW
More Green Datacenter data centers
- Green Datacenter ZRH2 (fka: Green Dielsdorf) Switzerland
- Green Datacenter ZRH3 (fka: Green Schlieren) Switzerland
- Green Datacenter ZRH4 (fka: Green Glattbrugg) Switzerland
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.