AtlasEdge DC Brussels BRU001

AtlasEdge DC Brussels BRU001 is an operational data center operated by AtlasEdge in Brussels, Belgium. Our footprint estimate of its power is about 8.5 MW.

Key facts

StatusOperational
OperatorAtlasEdge
Facility power8.5 MW (range 4.3 MW to 14 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 7,103 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 3,600 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks6 networks
PeeringDB.
Also known asBRU001
AddressMercuriusstraat 30, Nossegem
Coordinates50.87203, 4.50363
Websiteatlasedge.com/data-centres/brussels

Power and grid

Nearest high-voltage substationWoluwe-Saint-Lambert - Sint-Lambrechts-Woluwe, 150 kV, 3.9 km away (Elia)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substation380 kV Station Verbrande Brug, 380 kV, 9.8 km away
HV substations within 10 km8
Power plants within 50 km2.4 GW in 19 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity151 g CO₂ per kWh (Belgium, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 33.5%, gas 20.8%, wind 18.6%, solar 14.5%, oil and other fossil 7.1%. Clean power: 72.1%
Industrial power priceEUR 0.133 per kWh (Belgium, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature10.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature38.6 °C (2001 to 2025)
Cooling degree days87 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.03 kWh per m² per day
Wind at 50 m6.7 m/s average
Water stress todayExtremely High (>80%) (Belgium)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does AtlasEdge DC Brussels BRU001 use?

We estimate the facility power at about 8.5 MW. Estimate from building footprint, low confidence.

How close is AtlasEdge DC Brussels BRU001 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Woluwe-Saint-Lambert - Sint-Lambrechts-Woluwe (150 kV), about 3.9 km away.

How clean is the power for AtlasEdge DC Brussels BRU001?

The grid in Belgium emits about 151 g CO₂ per kWh (2025). Largest sources: nuclear 33.5%, gas 20.8%, wind 18.6%.

Who operates AtlasEdge DC Brussels BRU001?

AtlasEdge.