AtlasEdge DC Hamburg HAM002
AtlasEdge DC Hamburg HAM002 is an operational data center operated by AtlasEdge in Ahrensburg, Germany. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | AtlasEdge |
| Networks | 7 networks PeeringDB. |
| Also known as | ITENOS Hamburg (HAM2) · Rechenzentrum AtlasEdge HAM002 |
| Address | Carl-Backhaus-Straße 21C |
| Coordinates | 53.67862, 10.27049 |
| Website | atlasedge.com/data-centres/hamburg |
Power and grid
| Nearest high-voltage substation | Umspannwerk Ahrensburg Nord, 110 kV, 1 km away (Schleswig-Holstein Netz) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Hamburg/Ost, 380 kV, 15.5 km away |
| HV substations within 10 km | 3 |
| Power plants within 50 km | 921 MW in 18 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34 °C (2001 to 2025) |
| Cooling degree days | 76 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.88 kWh per m² per day |
| Wind at 50 m | 6.9 m/s average |
| Water stress today | Low - Medium (10-20%) (Schleswig-Holstein) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is AtlasEdge DC Hamburg HAM002 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Ahrensburg Nord (110 kV), about 1 km away.
How clean is the power for AtlasEdge DC Hamburg HAM002?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates AtlasEdge DC Hamburg HAM002?
AtlasEdge.
Data centers near Ahrensburg
- Akquinet HAM03 10.0 km
- GlobalConnect Hamburg (HAM1) 17.4 km
- NTT Hamburg 1 Data Center (HAM1) 17.4 km
- Akquinet HAM02 17.5 km
- Akquinet HAM01 17.8 km
- Akquinet NOR01 18.4 km
- Stadtwerke Norderstedt RZ1 18.4 km
- AtlasEdge DC Hamburg HAM001 18.9 km
More AtlasEdge data centers
- AtlasEdge DC Berlin BER001 Germany
- AtlasEdge DC Düsseldorf DUS001 Germany
- AtlasEdge DC Brussels BRU001 Belgium
- AtlasEdge DC Leverkusen LEV001 Germany
- AtlasEdge DC Hamburg HAM001 Germany
- AtlasEdge DC Lisbon LIS001 Portugal
- AtlasEdge DC Manchester MAN001 United Kingdom
- AtlasEdge DC Stuttgart GRP10 Germany
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.