China Mobile International - GNC Hong Kong
China Mobile International - GNC Hong Kong is an operational data center operated by China Mobile International in Hong Kong, Hong Kong SAR China. Our footprint estimate of its power is about 41 MW. Likely chips: Huawei Ascend and NVIDIA China-market GPUs (guess).
Key facts
| Status | Operational |
|---|---|
| Operator | China Mobile International |
| Facility power | 41 MW (range 20 MW to 65 MW) Estimate from building footprint, low confidence. Footprint estimate: about 5,663 m² building outline x 6 floor(s) x 1.2 kW/m². |
| AI chips | Huawei Ascend and NVIDIA China-market GPUs Guess from the operator, not confirmed. Chinese operators use Huawei Ascend and export-limited NVIDIA chips. |
| GPU capacity if all AI | about 18,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 27 networks PeeringDB. |
| Address | 3 Chun Cheong St, Tseung Kwan O Industrial Estate |
| Coordinates | 22.28905, 114.27197 |
| Website | isolutions.cmi.chinamobile.com/en/product/data-center/hong-kong-global |
Power and grid
| Nearest high-voltage substation | 將軍澳400仟伏變電站 Tseung Kwan O 400kV Substation, 400 kV, 4.9 km away (中華電力有限公司 CLP Power Hong Kong Limited) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 5 |
| Power plants within 50 km | 23 GW in 13 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 673 g CO₂ per kWh (Hong Kong SAR China, 2024) Average of all power made in the area. Ember. |
| Grid power mix | gas 63.8%, coal 33.5%, oil and other fossil 1.2%, solar 1%. Clean power: 1.5% |
Climate and water
| Average temperature | 23.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.6 °C (2001 to 2025) |
| Cooling degree days | 2,112 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.14 kWh per m² per day |
| Wind at 50 m | 5.6 m/s average |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does China Mobile International - GNC Hong Kong use?
We estimate the facility power at about 41 MW. Estimate from building footprint, low confidence.
What chips does China Mobile International - GNC Hong Kong use?
No chips are reported. Based on the operator, the likely chips are Huawei Ascend and NVIDIA China-market GPUs.
How close is China Mobile International - GNC Hong Kong to the power grid?
The nearest high-voltage substation in OpenStreetMap is 將軍澳400仟伏變電站 Tseung Kwan O 400kV Substation (400 kV), about 4.9 km away.
How clean is the power for China Mobile International - GNC Hong Kong?
The grid in Hong Kong SAR China emits about 673 g CO₂ per kWh (2024). Largest sources: gas 63.8%, coal 33.5%, oil and other fossil 1.2%.
Who operates China Mobile International - GNC Hong Kong?
China Mobile International.
Data centers near Hong Kong
- Global Switch Hong Kong 170 m
- Telehouse - Hong Kong CCC (HKCOLO TKO) 326 m · 2.2 MW
- Data center in LOHAS Park 361 m · 22 MW
- TOWNGAS TELECOM DATA CENTRE 2 363 m · 1.6 MW
- NTT Com Asia Hong Kong Financial Data Center 389 m · 9.8 MW
- Equinix HK5 - Hong Kong 518 m · 1.1 MW
- MEGA Plus (iAdvantage Hong Kong) 536 m · 19 MW
- Pacnet HK DLS 632 m
More China Mobile International data centers
- China Mobile International - Singapore DC Singapore
- China Mobile International - London DC United Kingdom
- China Mobile International - Data Zone Data Center (Thailand) Thailand
- China Mobile International - Frankfurt DC Germany
- China Mobile International - GIC Hong Kong Hong Kong SAR China