Equinix HK5 - Hong Kong
Equinix HK5 - Hong Kong is an operational data center operated by Equinix in Tseung Kwan O, Hong Kong SAR China. Our footprint estimate of its power is about 1.1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 1.1 MW (range 0.4 MW to 2.8 MW) Estimate from building footprint, low confidence. Footprint estimate: about 9,187 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 470 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 11 networks, 3 internet exchanges PeeringDB. |
| Also known as | Mega Plus |
| Address | Tower 2, 299 Wan Po Rd |
| Coordinates | 22.29300, 114.27464 |
| Website | equinix.com/locations/asia-colocation/hong-kong-colocation/hong-kong-data-center/hk5 |
Power and grid
| Nearest high-voltage substation | 將軍澳400仟伏變電站 Tseung Kwan O 400kV Substation, 400 kV, 4.6 km away (中華電力有限公司 CLP Power Hong Kong Limited) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 4 |
| Power plants within 50 km | 24 GW in 14 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 673 g CO₂ per kWh (Hong Kong SAR China, 2024) Average of all power made in the area. Ember. |
| Grid power mix | gas 63.8%, coal 33.5%, oil and other fossil 1.2%, solar 1%. Clean power: 1.5% |
Climate and water
| Average temperature | 23.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.6 °C (2001 to 2025) |
| Cooling degree days | 2,112 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.14 kWh per m² per day |
| Wind at 50 m | 5.6 m/s average |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix HK5 - Hong Kong use?
We estimate the facility power at about 1.1 MW. Estimate from building footprint, low confidence.
How close is Equinix HK5 - Hong Kong to the power grid?
The nearest high-voltage substation in OpenStreetMap is 將軍澳400仟伏變電站 Tseung Kwan O 400kV Substation (400 kV), about 4.6 km away.
How clean is the power for Equinix HK5 - Hong Kong?
The grid in Hong Kong SAR China emits about 673 g CO₂ per kWh (2024). Largest sources: gas 63.8%, coal 33.5%, oil and other fossil 1.2%.
Who operates Equinix HK5 - Hong Kong?
Equinix.
Data centers near Tseung Kwan O
- MEGA Plus (iAdvantage Hong Kong) 108 m · 19 MW
- Mega IDC 208 m · 1.5 MW
- Telehouse - Hong Kong CCC (HKCOLO TKO) 248 m · 2.2 MW
- China Mobile International - GNC Hong Kong 518 m · 41 MW
- TOWNGAS TELECOM DATA CENTRE 2 683 m · 1.6 MW
- Global Switch Hong Kong 689 m
- NTT Com Asia Hong Kong Financial Data Center 848 m · 9.8 MW
- Data center in LOHAS Park 879 m · 22 MW
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.