NTT Com Asia Hong Kong Financial Data Center
NTT Com Asia Hong Kong Financial Data Center is an operational data center operated by NTT Global Data Centers in Tseung Kwan O, Hong Kong SAR China. Our footprint estimate of its power is about 9.8 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | NTT Global Data Centers |
| Facility power | 9.8 MW (range 4.9 MW to 16 MW) Estimate from building footprint, low confidence. Footprint estimate: about 8,175 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,200 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 9 networks, 2 internet exchanges PeeringDB. |
| Also known as | 香港交易所將軍澳數據中心 HKEx Tseung Kwan O Data Centre |
| Address | 6 Chun Kwong St |
| Coordinates | 22.28561, 114.27262 |
| Website | services.global.ntt/en-us/services-and-products/global-data-centers/global-locations/asia-pacific/financial-data-center-1-and-2 |
Power and grid
| Nearest high-voltage substation | 將軍澳400仟伏變電站 Tseung Kwan O 400kV Substation, 400 kV, 5.3 km away (中華電力有限公司 CLP Power Hong Kong Limited) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 5 |
| Power plants within 50 km | 22 GW in 12 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 673 g CO₂ per kWh (Hong Kong SAR China, 2024) Average of all power made in the area. Ember. |
| Grid power mix | gas 63.8%, coal 33.5%, oil and other fossil 1.2%, solar 1%. Clean power: 1.5% |
Climate and water
| Average temperature | 23.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.6 °C (2001 to 2025) |
| Cooling degree days | 2,112 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.14 kWh per m² per day |
| Wind at 50 m | 5.6 m/s average |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does NTT Com Asia Hong Kong Financial Data Center use?
We estimate the facility power at about 9.8 MW. Estimate from building footprint, low confidence.
How close is NTT Com Asia Hong Kong Financial Data Center to the power grid?
The nearest high-voltage substation in OpenStreetMap is 將軍澳400仟伏變電站 Tseung Kwan O 400kV Substation (400 kV), about 5.3 km away.
How clean is the power for NTT Com Asia Hong Kong Financial Data Center?
The grid in Hong Kong SAR China emits about 673 g CO₂ per kWh (2024). Largest sources: gas 63.8%, coal 33.5%, oil and other fossil 1.2%.
Who operates NTT Com Asia Hong Kong Financial Data Center?
NTT Global Data Centers.
Data centers near Tseung Kwan O
- TOWNGAS TELECOM DATA CENTRE 2 245 m · 1.6 MW
- Pacnet HK DLS 272 m
- Data center in LOHAS Park 287 m · 22 MW
- Global Switch Hong Kong 291 m
- China Mobile International - GNC Hong Kong 389 m · 41 MW
- Digital Realty Hong Kong HKG10 416 m
- China Unicom (Hong Kong) Global Center 429 m
- Telehouse - Hong Kong CCC (HKCOLO TKO) 607 m · 2.2 MW
More NTT Global Data Centers data centers
- NTT VA10 United States
- NTT Frankfurt 2 Data Center (FRA2) Germany
- NTT PH1 Datacenter United States
- NTT Japan
- NTTData Data Center United States
- NTT Hemel Hempstead 4 Data Center (HH4) United Kingdom
- NTT Berlin 1 Data Center (BER1) Germany
- NTT London 1 United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.