NTT Com Asia Hong Kong Financial Data Center

NTT Com Asia Hong Kong Financial Data Center is an operational data center operated by NTT Global Data Centers in Tseung Kwan O, Hong Kong SAR China. Our footprint estimate of its power is about 9.8 MW.

Key facts

StatusOperational
OperatorNTT Global Data Centers
Facility power9.8 MW (range 4.9 MW to 16 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 8,175 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 4,200 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks9 networks, 2 internet exchanges
PeeringDB.
Also known as香港交易所將軍澳數據中心 HKEx Tseung Kwan O Data Centre
Address6 Chun Kwong St
Coordinates22.28561, 114.27262
Websiteservices.global.ntt/en-us/services-and-products/global-data-centers/global-locations/asia-pacific/financial-data-center-1-and-2

Power and grid

Nearest high-voltage substation將軍澳400仟伏變電站 Tseung Kwan O 400kV Substation, 400 kV, 5.3 km away (中華電力有限公司 CLP Power Hong Kong Limited)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km5
Power plants within 50 km22 GW in 12 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity673 g CO₂ per kWh (Hong Kong SAR China, 2024)
Average of all power made in the area. Ember.
Grid power mixgas 63.8%, coal 33.5%, oil and other fossil 1.2%, solar 1%. Clean power: 1.5%

Climate and water

Average temperature23.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature35.6 °C (2001 to 2025)
Cooling degree days2,112 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.14 kWh per m² per day
Wind at 50 m5.6 m/s average

Satellite view

Questions

How much power does NTT Com Asia Hong Kong Financial Data Center use?

We estimate the facility power at about 9.8 MW. Estimate from building footprint, low confidence.

How close is NTT Com Asia Hong Kong Financial Data Center to the power grid?

The nearest high-voltage substation in OpenStreetMap is 將軍澳400仟伏變電站 Tseung Kwan O 400kV Substation (400 kV), about 5.3 km away.

How clean is the power for NTT Com Asia Hong Kong Financial Data Center?

The grid in Hong Kong SAR China emits about 673 g CO₂ per kWh (2024). Largest sources: gas 63.8%, coal 33.5%, oil and other fossil 1.2%.

Who operates NTT Com Asia Hong Kong Financial Data Center?

NTT Global Data Centers.