ColoCenter.com - Manchester NH
ColoCenter.com - Manchester NH is an operational data center operated by G4 Communications in Manchester, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | G4 Communications |
| Address | 77 Sundial Avenue |
| Coordinates | 42.97198, -71.46888 |
| Website | ColoCenter.com |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 115 kV, 3.1 km away (Eversource) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 230 kV, 8.3 km away |
| HV substations within 10 km | 8 |
| Utility | Liberty Utilities (Granite State Electri (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | ISNE |
| Nearest gas pipeline | EnergyNorth Nat Gas Co, interstate pipeline, 1.7 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 1.2 GW in 58 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 180 g CO₂ per kWh (New Hampshire, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 55.3%, gas 27%, hydro 6.9%, bioenergy 4.1%, wind 2.4%. Clean power: 70.7% |
| Industrial power price | USD 0.173 per kWh (New Hampshire, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 8.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 37.9 °C (2001 to 2025) |
| Cooling degree days | 297 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.71 kWh per m² per day |
| Wind at 50 m | 4.5 m/s average |
| Water stress today | Low - Medium (10-20%) (New Hampshire) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is ColoCenter.com - Manchester NH to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (115 kV), about 3.1 km away. The local utility is Liberty Utilities (Granite State Electri, in the ISNE balancing area.
How clean is the power for ColoCenter.com - Manchester NH?
The grid in New Hampshire emits about 180 g CO₂ per kWh (2025). Largest sources: nuclear 55.3%, gas 27%, hydro 6.9%.
Who operates ColoCenter.com - Manchester NH?
G4 Communications.
Data centers near Manchester
- Crown Castle Manchester (1 Sundial Ave) 85 m
- Consolidated - 770 Elm St. 1.9 km
- ColoSpace - Bedford, NH 4.9 km
- Navisite Andover 37.2 km
- TierPoint Boston - Andover 38.3 km · 6.8 MW
- Markley Group Lowell 40.3 km · 17 MW
- Information Technology Data Center 42.2 km · 1.4 MW
- Prov.net CHF1 (Boston North) 43.2 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.