TierPoint Boston - Andover

TierPoint Boston - Andover is an operational data center operated by TierPoint in Andover, United States. Our footprint estimate of its power is about 6.8 MW.

Key facts

StatusOperational
OperatorTierPoint
Facility power6.8 MW (range 3.4 MW to 11 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 5,682 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 2,900 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks2 networks
PeeringDB.
Address15 Shattuck Road
Coordinates42.68569, -71.20869
Websitetierpoint.com

Power and grid

UtilityMassachusetts Electric Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityISNE
Nearest gas pipelineTennessee Gas Pipeline, interstate pipeline, 100 m away
US Energy Information Administration pipeline map. Straight-line distance.
Grid carbon intensity268 g CO₂ per kWh (New York, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 45.4%, nuclear 20.7%, hydro 18.5%, solar 7.6%, wind 5%. Clean power: 52.9%
Industrial power priceUSD 0.105 per kWh (New York, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature9.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature38 °C (2001 to 2025)
Cooling degree days356 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.82 kWh per m² per day
Wind at 50 m4.7 m/s average
Water stress todayLow - Medium (10-20%) (New York)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does TierPoint Boston - Andover use?

We estimate the facility power at about 6.8 MW. Estimate from building footprint, low confidence.

How clean is the power for TierPoint Boston - Andover?

The grid in New York emits about 268 g CO₂ per kWh (2025). Largest sources: gas 45.4%, nuclear 20.7%, hydro 18.5%.

Who operates TierPoint Boston - Andover?

TierPoint.

Data centers near Andover

More TierPoint data centers