Data center in Henderson
Data center in Henderson is an operational data center in Henderson, United States. Our footprint estimate of its power is about 13 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 13 MW (range 6.7 MW to 21 MW) Estimate from building footprint, low confidence. Footprint estimate: about 11,193 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 5,600 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 36.67928, -78.37417 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 115 kV, 300 m away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 500 kV, 36.2 km away |
| HV substations within 10 km | 8 |
| Utility | Mecklenburg Electric Cooperative (cooperative) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Transcontinental Gas PL, interstate pipeline, 10.2 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 2.5 GW in 40 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 357 g CO₂ per kWh (Virginia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39% |
| Industrial power price | USD 0.100 per kWh (Virginia, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 14.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.7 °C (2001 to 2025) |
| Cooling degree days | 908 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.37 kWh per m² per day |
| Wind at 50 m | 4.5 m/s average |
| Water stress today | Medium - High (20-40%) (Virginia) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data center in Henderson use?
We estimate the facility power at about 13 MW. Estimate from building footprint, low confidence.
How close is Data center in Henderson to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (115 kV), about 300 m away. The local utility is Mecklenburg Electric Cooperative, in the PJM balancing area.
How clean is the power for Data center in Henderson?
The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.
Data centers near Henderson
- Data center in Henderson 164 m · 33 MW
- Data center in Henderson 240 m · 4.2 MW
- Microsoft Azure Voyager-EUS2 349 m · 1.8 MW
- Data center in Henderson 399 m · 9.2 MW
- Data center in Henderson 437 m · 18 MW
- Microsoft Boydton Data Center 690 m · 243 MW
- Data center in Henderson 1.2 km · 18 MW
- Data center in Henderson 1.5 km · 25 MW
Sources
Correct this page or get the data