Data center in Minchinbury
Data center in Minchinbury is a data center under construction in Minchinbury, Australia. Our footprint estimate of its power is about 12 MW.
Key facts
| Status | Under construction |
|---|---|
| Facility power | 12 MW (range 5.9 MW to 19 MW) Estimate from building footprint, low confidence. Footprint estimate: about 9,766 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 5,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | -33.81089, 150.83859 |
Power and grid
| Nearest high-voltage substation | Sydney West SVC, 330 kV, 900 m away (TransGrid) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 18 |
| Power plants within 50 km | 229 MW in 5 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 518 g CO₂ per kWh (Australia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 42.9%, solar 20.4%, gas 15.5%, wind 13.8%, hydro 4.4%. Clean power: 39.8% |
Climate and water
| Average temperature | 18.7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.9 °C (2001 to 2025) |
| Cooling degree days | 673 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.65 kWh per m² per day |
| Wind at 50 m | 5.2 m/s average |
| Water stress today | High (40-80%) (New South Wales) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data center in Minchinbury use?
We estimate the facility power at about 12 MW. Estimate from building footprint, low confidence.
How close is Data center in Minchinbury to the power grid?
The nearest high-voltage substation in OpenStreetMap is Sydney West SVC (330 kV), about 900 m away.
How clean is the power for Data center in Minchinbury?
The grid in Australia emits about 518 g CO₂ per kWh (2025). Largest sources: coal 42.9%, solar 20.4%, gas 15.5%.
Data centers near Minchinbury
- AWS Asia Pacific (Sydney) Region Data Centre 159 m · 10 MW
- CDC Sydney EC1 711 m · 17 MW
- CDC Eastern Creek Campus EC5 841 m · 14 MW
- CDC Eastern Creek Campus EC4 870 m · 17 MW
- AWS Asia Pacific (Sydney) Region Data Centre 3.4 km · 14 MW
- AirTrunk SYD3 Sydney West 3.7 km · 11 MW
- Digital Realty Sydney SYD10 4.0 km · 12 MW
- AirTrunk SYD1 Sydney West 4.1 km · 6.3 MW
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.