Digital Realty Sydney SYD10
Digital Realty Sydney SYD10 is an operational data center operated by Digital Realty in Erskine Park, Australia. Our footprint estimate of its power is about 12 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Digital Realty |
| Facility power | 12 MW (range 5.8 MW to 19 MW) Estimate from building footprint, low confidence. Footprint estimate: about 9,698 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 5,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 3 networks, 2 internet exchanges PeeringDB. |
| Also known as | Digital Realty Sydney SYD11 · Digital Erskine Park 2 · Digital Erskine Park 1 |
| Address | 1-12 Templar |
| Coordinates | -33.81615, 150.79588 |
| Website | digitalrealty.com |
Power and grid
| Nearest high-voltage substation | Mamre Zone Substation, 132 kV, 500 m away (Endeavour Energy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Sydney West Bulk Supply Substation, 330 kV, 3 km away |
| HV substations within 10 km | 15 |
| Power plants within 50 km | 229 MW in 5 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 518 g CO₂ per kWh (Australia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 42.9%, solar 20.4%, gas 15.5%, wind 13.8%, hydro 4.4%. Clean power: 39.8% |
Climate and water
| Average temperature | 18.7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.9 °C (2001 to 2025) |
| Cooling degree days | 673 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.65 kWh per m² per day |
| Wind at 50 m | 5.2 m/s average |
| Water stress today | High (40-80%) (New South Wales) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Digital Realty Sydney SYD10 use?
We estimate the facility power at about 12 MW. Estimate from building footprint, low confidence.
How close is Digital Realty Sydney SYD10 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Mamre Zone Substation (132 kV), about 500 m away.
How clean is the power for Digital Realty Sydney SYD10?
The grid in Australia emits about 518 g CO₂ per kWh (2025). Largest sources: coal 42.9%, solar 20.4%, gas 15.5%.
Who operates Digital Realty Sydney SYD10?
Digital Realty.
Data centers near Erskine Park
- Telstra 1.6 km · 24 MW
- Microsoft SYD06 Data Centre 2.9 km · 20 MW
- CDC Eastern Creek Campus EC5 3.8 km · 14 MW
- CDC Eastern Creek Campus EC4 3.9 km · 17 MW
- CDC Sydney EC1 3.9 km · 17 MW
- Data center in Minchinbury 4.0 km · 12 MW
- AWS Asia Pacific (Sydney) Region Data Centre 4.1 km · 10 MW
- AWS Asia Pacific (Sydney) Region Data Centre 7.2 km · 14 MW
More Digital Realty data centers
- Digital Realty CH1 - Chicago United States
- Digital Realty IAD39 United States
- Digital Realty IAD51 United States
- Digital Realty IAD44 United States
- Digital Realty IAD41 United States
- Digital Realty Singapore SIN11 Singapore
- Digital Realty Toronto YYZ11 Canada
- Digital Realty IAD43 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.