Data center in Sant Cugat del Vallès is an operational data center in Sant Cugat del Vallès, Spain. Our footprint estimate of its power is about 7.9 MW.

Key facts

StatusOperational
Facility power7.9 MW (range 3.2 MW to 20 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 66,165 m² site outline x 0.12 kW per m² of land.
GPU capacity if all AIabout 3,400 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Coordinates41.48383, 2.10519

Power and grid

Nearest high-voltage substationCodonyers, 220 kV, 800 m away (Red Eléctrica de España)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km28
Power plants within 50 km2.5 GW in 3 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity154 g CO₂ per kWh (Spain, 2025)
Average of all power made in the area. Ember.
Grid power mixsolar 21.9%, gas 21.5%, wind 20.4%, nuclear 18.8%, hydro 11.4%. Clean power: 74.6%
Industrial power priceEUR 0.105 per kWh (Spain, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature15.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature38.2 °C (2001 to 2025)
Cooling degree days687 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.38 kWh per m² per day
Wind at 50 m4.3 m/s average
Water stress todayHigh (40-80%) (Spain)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Data center in Sant Cugat del Vallès use?

We estimate the facility power at about 7.9 MW. Estimate from building footprint, low confidence.

How close is Data center in Sant Cugat del Vallès to the power grid?

The nearest high-voltage substation in OpenStreetMap is Codonyers (220 kV), about 800 m away.

How clean is the power for Data center in Sant Cugat del Vallès?

The grid in Spain emits about 154 g CO₂ per kWh (2025). Largest sources: solar 21.9%, gas 21.5%, wind 20.4%.

Data centers near Sant Cugat del Vallès

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.