Data centre OVH Cloud MIL1 is an operational data center in Sant'Angelo Lodigiano, Italy. Our footprint estimate of its power is about 8.3 MW.

Key facts

StatusOperational
Facility power8.3 MW (range 3.3 MW to 21 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 69,067 m² site outline x 0.12 kW per m² of land.
GPU capacity if all AIabout 3,500 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Coordinates45.19024, 9.39406

Power and grid

Nearest high-voltage substationCorteolona CS, 132 kV, 3.4 km away (Enel Distribuzione)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationChignolo Po, 380 kV, 11 km away
HV substations within 10 km5
Power plants within 50 km7.3 GW in 15 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity285 g CO₂ per kWh (Italy, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 47.4%, solar 16.8%, hydro 15.7%, wind 8.1%, bioenergy 5.9%. Clean power: 48.7%
Industrial power priceEUR 0.173 per kWh (Italy, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature13 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39 °C (2001 to 2025)
Cooling degree days529 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.78 kWh per m² per day
Wind at 50 m3.6 m/s average
Water stress todayHigh (40-80%) (Italy)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Data centre OVH Cloud MIL1 use?

We estimate the facility power at about 8.3 MW. Estimate from building footprint, low confidence.

How close is Data centre OVH Cloud MIL1 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Corteolona CS (132 kV), about 3.4 km away.

How clean is the power for Data centre OVH Cloud MIL1?

The grid in Italy emits about 285 g CO₂ per kWh (2025). Largest sources: gas 47.4%, solar 16.8%, hydro 15.7%.