DataBank Chicago (ORD3)
DataBank Chicago (ORD3) is an operational data center operated by DataBank in Mount Prospect, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | DataBank |
| Networks | 4 networks PeeringDB. |
| Also known as | CDC3 - 800 E Business Center Dr |
| Address | 800 E Business Center Dr |
| Coordinates | 42.07805, -87.92355 |
| Website | databank.com/data-centers/chicago/mount-prospect |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 138 kV, 1.7 km away (Commonwealth Edison) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Des Plaines 138kV-345kV Substation, 345 kV, 3.8 km away |
| HV substations within 10 km | 14 |
| Utility | Commonwealth Edison Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Northern Illinois Gas Co, intrastate pipeline, 1.4 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 3.3 GW in 29 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 247 g CO₂ per kWh (Illinois, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3% |
| Industrial power price | USD 0.113 per kWh (Illinois, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 9.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.5 °C (2001 to 2025) |
| Cooling degree days | 465 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.67 kWh per m² per day |
| Wind at 50 m | 6.8 m/s average |
| Water stress today | Medium - High (20-40%) (Illinois) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is DataBank Chicago (ORD3) to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 1.7 km away. The local utility is Commonwealth Edison Co, in the PJM balancing area.
How clean is the power for DataBank Chicago (ORD3)?
The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.
Who operates DataBank Chicago (ORD3)?
DataBank.
Data centers near Mount Prospect
- NETRIX - MTP 653 m
- GigeNET CHI3 6.0 km
- Prime Data Centers 6.9 km · 11 MW
- Aligned Data Center 6.9 km · 40 MW
- Microsoft CHI12 Data Center 7.2 km · 13 MW
- T5@Chicago 7.3 km · 14 MW
- Stream Data Centers 7.8 km · 17 MW
- EdgeConnex Data Center 7.8 km · 7.1 MW
More DataBank data centers
- Databank Orangeburg (LGA3) United States
- DataBank Salt Lake City (SLC2) United States
- DataBank Ashburn (IAD1) United States
- DataBank Dallas (DFW3) United States
- DataBank Las Vegas (LAS1) United States
- DataBank Dallas (DFW4) United States
- DataBank Minneapolis (MSP3) United States
- DataBank Seattle (SEA2) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.