DataBank Kansas City (MCI3)
DataBank Kansas City (MCI3) is an operational data center operated by DataBank in Lenexa, United States. Our footprint estimate of its power is about 4.1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | DataBank |
| Facility power | 4.1 MW (range 2.1 MW to 6.6 MW) Estimate from building footprint, low confidence. Footprint estimate: about 3,423 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 4 networks PeeringDB. |
| Also known as | Data Center Lenexa |
| Address | 11200 Lakeview Ave |
| Coordinates | 38.92519, -94.77028 |
| Website | databank.com/data-centers/kansas-city/south-lake-data-center-3 |
Power and grid
| Nearest high-voltage substation | College Substation, 161 kV, 600 m away (Evergy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Craig Substation, 345 kV, 3.5 km away |
| HV substations within 10 km | 20 |
| Utility | City Of Kansas City (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | SWPP |
| Nearest gas pipeline | Southern Star Central Gas PL Co, interstate pipeline, 3.3 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 4.8 GW in 26 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 332 g CO₂ per kWh (Kansas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 46.9%, coal 30.6%, nuclear 14.7%, gas 6.5%, solar 1.1%. Clean power: 62.8% |
| Industrial power price | USD 0.085 per kWh (Kansas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 12.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 44.6 °C (2001 to 2025) |
| Cooling degree days | 811 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.23 kWh per m² per day |
| Wind at 50 m | 6.8 m/s average |
| Water stress today | High (40-80%) (Kansas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does DataBank Kansas City (MCI3) use?
We estimate the facility power at about 4.1 MW. Estimate from building footprint, low confidence.
How close is DataBank Kansas City (MCI3) to the power grid?
The nearest high-voltage substation in OpenStreetMap is College Substation (161 kV), about 600 m away. The local utility is City Of Kansas City, in the SWPP balancing area.
How clean is the power for DataBank Kansas City (MCI3)?
The grid in Kansas emits about 332 g CO₂ per kWh (2025). Largest sources: wind 46.9%, coal 30.6%, nuclear 14.7%.
Who operates DataBank Kansas City (MCI3)?
DataBank.
Data centers near Lenexa
- Data center in Lenexa 244 m
- TierPoint Kansas City - Lenexa 2.2 km · 5.5 MW
- LightEdge Kansas City Cavern (KCI2) 3.4 km
- WANSEC DC16 6.3 km
- DataBank Kansas City (MCI2) 7.7 km
- Data center in Olathe 7.9 km · 14 MW
- U.S. Bank National Data Process Center 8.2 km · 26 MW
- Netrality Kansas City Metro – KC2 | 7801 Nieman 8.5 km
More DataBank data centers
- Databank Orangeburg (LGA3) United States
- DataBank Salt Lake City (SLC2) United States
- DataBank Ashburn (IAD1) United States
- DataBank Dallas (DFW3) United States
- DataBank Las Vegas (LAS1) United States
- DataBank Dallas (DFW4) United States
- DataBank Minneapolis (MSP3) United States
- DataBank Seattle (SEA2) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.