DataBank Pittsburgh (PIT2)
DataBank Pittsburgh (PIT2) is an operational data center operated by DataBank in Pittsburgh, United States. Our footprint estimate of its power is about 8.3 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | DataBank |
| Facility power | 8.3 MW (range 4.2 MW to 13 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,940 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 1 networks PeeringDB. |
| Also known as | DataBank Pittsburgh PIT2 |
| Address | 35 Summit Park Dr |
| Coordinates | 40.45132, -80.19003 |
| Website | databank.com/data-centers/pittsburgh/west-pittsburgh-data-center |
Power and grid
| Utility | Pennsylvania Power Co (investor owned) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | PJM |
| Nearest gas pipeline | Columbia Gas Trans Co, interstate pipeline, 3.8 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 536 g CO₂ per kWh (Ohio, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 54.9%, coal 24.4%, nuclear 11.7%, solar 5.8%, wind 2%. Clean power: 20% |
| Industrial power price | USD 0.098 per kWh (Ohio, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 10.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 37.7 °C (2001 to 2025) |
| Cooling degree days | 470 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.72 kWh per m² per day |
| Wind at 50 m | 4.4 m/s average |
| Water stress today | Low - Medium (10-20%) (Ohio) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does DataBank Pittsburgh (PIT2) use?
We estimate the facility power at about 8.3 MW. Estimate from building footprint, low confidence.
How clean is the power for DataBank Pittsburgh (PIT2)?
The grid in Ohio emits about 536 g CO₂ per kWh (2025). Largest sources: gas 54.9%, coal 24.4%, nuclear 11.7%.
Who operates DataBank Pittsburgh (PIT2)?
DataBank.
Data centers near Pittsburgh
- EdgeConneX Pittsburgh (EDCPIT01) 12.6 km
- Expedient Pittsburgh - Green Tree 12.8 km · 5 MW
- Zayo Pittsburgh - 2500 Allegheny Center Mall 15.5 km
- Expedient Pittsburgh - Nova Place 15.6 km
- Crown Castle Pittsburgh (Allegheny Center Mall) 15.6 km
- Citynet Pittsburgh 15.8 km
- DQE Communications (Downtown Pittsburgh) 16.1 km
- H5 Data Centers Pittsburgh (PA02) 17.7 km
More DataBank data centers
- Databank Orangeburg (LGA3) United States
- DataBank Salt Lake City (SLC2) United States
- DataBank Ashburn (IAD1) United States
- DataBank Dallas (DFW3) United States
- DataBank Las Vegas (LAS1) United States
- DataBank Dallas (DFW4) United States
- DataBank Minneapolis (MSP3) United States
- DataBank Seattle (SEA2) United States