Datacenter Orange is an operational data center operated by Orange in Vélizy-Villacoublay, France. Our footprint estimate of its power is about 24 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Orange |
| Facility power | 24 MW (range 12 MW to 39 MW) Estimate from building footprint, low confidence. Footprint estimate: about 4,010 m² building outline x 5 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 10,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 48.78658, 2.21860 |
Power and grid
| Nearest high-voltage substation | Robinson, 225 kV, 2.5 km away (SNCF Réseau) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 21 |
| Power plants within 50 km | 1.9 GW in 47 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38.2 °C (2001 to 2025) |
| Cooling degree days | 106 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.19 kWh per m² per day |
| Wind at 50 m | 6.4 m/s average |
| Water stress today | Low - Medium (10-20%) (France) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Datacenter Orange use?
We estimate the facility power at about 24 MW. Estimate from building footprint, low confidence.
How close is Datacenter Orange to the power grid?
The nearest high-voltage substation in OpenStreetMap is Robinson (225 kV), about 2.5 km away.
How clean is the power for Datacenter Orange?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates Datacenter Orange?
Orange.
Data centers near Vélizy-Villacoublay
- dc2scale PAR4x (Meudon) 66 m
- Equinix PA13X 318 m · 79 MW
- ETIX Paris #3 656 m · 1.3 MW
- Multicoms Paris (Velizy) 658 m
- dc2scale PAR3 (Vélizy-Villacoublay) 736 m · 0.8 MW
- Cogent Velizy 837 m
- UltraEdge Velizy 852 m · 8.1 MW
- Cogent Paris 2 894 m
More Orange data centers
- Orange - Aubervilliers France
- Paris St Amand France
- Marseille St-Mauront France
- Station d'atterrage France
- Datacenter Orange Archives France
- Lille Boitelle France
- Lyon Sévigné France
- Marseille Nedelec France
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.