Station d'atterrage
Station d'atterrage is an operational data center operated by orange in Saint-Hilaire-de-Riez, France. Our footprint estimate of its power is about 1.6 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | orange |
| Facility power | 1.6 MW (range 0.6 MW to 3.9 MW) Estimate from building footprint, low confidence. Footprint estimate: about 13,109 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 680 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 46.73865, -1.99021 |
Power and grid
| Nearest high-voltage substation | Poste électrique de Gué au Roux, 225 kV, 9 km away (RTE) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 2 |
| Power plants within 50 km | 537 MW in 9 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 13.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 31.6 °C (2001 to 2025) |
| Cooling degree days | 105 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.7 kWh per m² per day |
| Wind at 50 m | 7.1 m/s average |
| Water stress today | Low - Medium (10-20%) (Pays de la Loire) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Station d'atterrage use?
We estimate the facility power at about 1.6 MW. Estimate from building footprint, low confidence.
How close is Station d'atterrage to the power grid?
The nearest high-voltage substation in OpenStreetMap is Poste électrique de Gué au Roux (225 kV), about 9 km away.
How clean is the power for Station d'atterrage?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates Station d'atterrage?
orange.
Data centers near Saint-Hilaire-de-Riez
- Etix Vendée #2 31.0 km · 3 MW
- ETIX Vendée #1 49.2 km
- Proginov 51.1 km · 11 MW
- SFR data center in Saint-Herblain 60.4 km · 2.6 MW
- UltraEdge Rezé 60.4 km · 1.5 MW
- ETIX Nantes #3 60.7 km · 4.7 MW
- OT - Armor 61.2 km · 6.1 MW
- Cogent Nantes 61.5 km
More orange data centers
- Datacenter Orange France
- Orange - Aubervilliers France
- Paris St Amand France
- Marseille St-Mauront France
- Datacenter Orange Archives France
- Lille Boitelle France
- Lyon Sévigné France
- Marseille Nedelec France
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.