OT - Armor

OT - Armor is an operational data center operated by Groupe Oceanet Technology in Saint-Herblain, France. Our footprint estimate of its power is about 6.1 MW.

Key facts

StatusOperational
OperatorGroupe Oceanet Technology
Facility power6.1 MW (range 3 MW to 9.7 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 1,692 m² building outline x 3 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 2,600 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks22 networks, 1 internet exchanges
PeeringDB.
Also known asOceanet Armor B · ETIX Nantes #1
Address2 Impasse Josephine BAKER, Oceanet Technology
Coordinates47.23143, -1.63100
Websiteoceanet-technology.com

Power and grid

Nearest high-voltage substationUnnamed substation, 225 kV, 4.9 km away (RTE)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km5
Power plants within 50 km1.9 GW in 22 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity41 g CO₂ per kWh (France, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9%
Industrial power priceEUR 0.098 per kWh (France, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature11.8 °C
NASA POWER, average of 2001 to 2025.
Highest temperature37.3 °C (2001 to 2025)
Cooling degree days121 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.48 kWh per m² per day
Wind at 50 m6.5 m/s average
Water stress todayLow - Medium (10-20%) (Pays de la Loire)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does OT - Armor use?

We estimate the facility power at about 6.1 MW. Estimate from building footprint, low confidence.

How close is OT - Armor to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (225 kV), about 4.9 km away.

How clean is the power for OT - Armor?

The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.

Who operates OT - Armor?

Groupe Oceanet Technology.

Data centers near Saint-Herblain

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.