OT - Armor
OT - Armor is an operational data center operated by Groupe Oceanet Technology in Saint-Herblain, France. Our footprint estimate of its power is about 6.1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Groupe Oceanet Technology |
| Facility power | 6.1 MW (range 3 MW to 9.7 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,692 m² building outline x 3 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,600 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 22 networks, 1 internet exchanges PeeringDB. |
| Also known as | Oceanet Armor B · ETIX Nantes #1 |
| Address | 2 Impasse Josephine BAKER, Oceanet Technology |
| Coordinates | 47.23143, -1.63100 |
| Website | oceanet-technology.com |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 225 kV, 4.9 km away (RTE) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 5 |
| Power plants within 50 km | 1.9 GW in 22 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 11.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 37.3 °C (2001 to 2025) |
| Cooling degree days | 121 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.48 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | Low - Medium (10-20%) (Pays de la Loire) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does OT - Armor use?
We estimate the facility power at about 6.1 MW. Estimate from building footprint, low confidence.
How close is OT - Armor to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (225 kV), about 4.9 km away.
How clean is the power for OT - Armor?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates OT - Armor?
Groupe Oceanet Technology.
Data centers near Saint-Herblain
- SFR data center in Saint-Herblain 847 m · 2.6 MW
- ETIX Nantes #3 2.9 km · 4.7 MW
- UltraEdge Rezé 6.6 km · 1.5 MW
- Cogent Nantes 6.8 km
- Bouygues Télécom data center in La Chapelle-sur-Erdre 7.9 km · 1.1 MW
- Sigma DC3 13.2 km · 3.7 MW
- Proginov 16.8 km · 11 MW
- Station d'atterrage 61.2 km · 1.6 MW