DCstar Datacenter Gent DCG

DCstar Datacenter Gent DCG is an operational data center operated by DCStar in Ghent, Belgium. Our footprint estimate of its power is about 3 MW.

Key facts

StatusOperational
OperatorDCStar
Facility power3 MW (range 1.5 MW to 4.8 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 2,475 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 1,300 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks7 networks, 1 internet exchanges
PeeringDB.
Also known asDatacenter Gent
AddressPoortakkerstraat 33, 9051 Gent
Coordinates51.02681, 3.68334
Websitedcstar.be/dcgent

Power and grid

Nearest high-voltage substationFlora, 150 kV, 4.7 km away (Elia)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationHorta, 380 kV, 11.2 km away
HV substations within 10 km7
Power plants within 50 km4.5 GW in 37 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity151 g CO₂ per kWh (Belgium, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 33.5%, gas 20.8%, wind 18.6%, solar 14.5%, oil and other fossil 7.1%. Clean power: 72.1%
Industrial power priceEUR 0.133 per kWh (Belgium, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature10.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature36.4 °C (2001 to 2025)
Cooling degree days66 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.13 kWh per m² per day
Wind at 50 m6.8 m/s average
Water stress todayExtremely High (>80%) (Belgium)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does DCstar Datacenter Gent DCG use?

We estimate the facility power at about 3 MW. Estimate from building footprint, low confidence.

How close is DCstar Datacenter Gent DCG to the power grid?

The nearest high-voltage substation in OpenStreetMap is Flora (150 kV), about 4.7 km away.

How clean is the power for DCstar Datacenter Gent DCG?

The grid in Belgium emits about 151 g CO₂ per kWh (2025). Largest sources: nuclear 33.5%, gas 20.8%, wind 18.6%.

Who operates DCstar Datacenter Gent DCG?

DCStar.