LCL Brussels West

LCL Brussels West is an operational data center operated by LCL Belgium in Aalst, Belgium. Our footprint estimate of its power is about 7 MW.

Key facts

StatusOperational
OperatorLCL Belgium
Facility power7 MW (range 3.5 MW to 11 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 5,839 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 3,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks7 networks, 1 internet exchanges
PeeringDB.
Also known asLCL Datacenter
AddressIndustrielaan 3A
Coordinates50.91315, 4.03804
Websitelcl.be

Power and grid

Nearest high-voltage substationAalst, 150 kV, 2.2 km away (Elia)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substation380kV Bruegel, 380 kV, 14 km away
HV substations within 10 km4
Power plants within 50 km5.7 GW in 29 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity151 g CO₂ per kWh (Belgium, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 33.5%, gas 20.8%, wind 18.6%, solar 14.5%, oil and other fossil 7.1%. Clean power: 72.1%
Industrial power priceEUR 0.133 per kWh (Belgium, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature10.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature36.4 °C (2001 to 2025)
Cooling degree days66 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.03 kWh per m² per day
Wind at 50 m6.8 m/s average
Water stress todayExtremely High (>80%) (Belgium)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does LCL Brussels West use?

We estimate the facility power at about 7 MW. Estimate from building footprint, low confidence.

How close is LCL Brussels West to the power grid?

The nearest high-voltage substation in OpenStreetMap is Aalst (150 kV), about 2.2 km away.

How clean is the power for LCL Brussels West?

The grid in Belgium emits about 151 g CO₂ per kWh (2025). Largest sources: nuclear 33.5%, gas 20.8%, wind 18.6%.

Who operates LCL Brussels West?

LCL Belgium.