Digital Realty London LHR17

Digital Realty London LHR17 is an operational data center operated by Digital Realty in West Drayton, United Kingdom. Our footprint estimate of its power is about 3.2 MW.

Key facts

StatusOperational
OperatorDigital Realty
Facility power3.2 MW (range 1.6 MW to 5.1 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 2,680 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 1,400 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks15 networks
PeeringDB.
Also known asDigital Realty LHR17
AddressUnit 1, Airport Gate Bath Road
Coordinates51.48225, -0.46022
Websitedigitalrealty.com/data-centers/london/unit-1-airport-gate-bath-road-middlesex

Power and grid

Nearest high-voltage substationLongford Substation, 132 kV, 3.1 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationNorth Hyde Substation, 275 kV, 3.9 km away
HV substations within 10 km10
Power plants within 50 km2.4 GW in 83 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity218 g CO₂ per kWh (United Kingdom, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2%

Climate and water

Average temperature10.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature34.9 °C (2001 to 2025)
Cooling degree days53 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.94 kWh per m² per day
Wind at 50 m7.1 m/s average
Water stress todayLow - Medium (10-20%) (England)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Digital Realty London LHR17 use?

We estimate the facility power at about 3.2 MW. Estimate from building footprint, low confidence.

How close is Digital Realty London LHR17 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Longford Substation (132 kV), about 3.1 km away.

How clean is the power for Digital Realty London LHR17?

The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.

Who operates Digital Realty London LHR17?

Digital Realty.

Data centers near West Drayton

More Digital Realty data centers