Digital Realty London LHR19
Digital Realty London LHR19 is an operational data center operated by Digital Realty in London, United Kingdom. Our footprint estimate of its power is about 5.1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Digital Realty |
| Facility power | 5.1 MW (range 2.5 MW to 8.1 MW) Estimate from building footprint, low confidence. Footprint estimate: about 847 m² building outline x 5 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,200 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 38 networks, 4 internet exchanges PeeringDB. |
| Also known as | London Stock Exchange datacenter · Digital Realty LHR19 |
| Address | Cloud House, Millharbour 47 |
| Coordinates | 51.49690, -0.01893 |
| Website | interxion.com |
Power and grid
| Nearest high-voltage substation | Westferry Circus Substation, 132 kV, 1.2 km away (UK Power Networks) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | West Ham Substation, 400 kV, 2.9 km away |
| HV substations within 10 km | 53 |
| Power plants within 50 km | 3.1 GW in 97 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 218 g CO₂ per kWh (United Kingdom, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2% |
Climate and water
| Average temperature | 10.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34 °C (2001 to 2025) |
| Cooling degree days | 46 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.97 kWh per m² per day |
| Wind at 50 m | 7.2 m/s average |
| Water stress today | Low - Medium (10-20%) (England) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Digital Realty London LHR19 use?
We estimate the facility power at about 5.1 MW. Estimate from building footprint, low confidence.
How close is Digital Realty London LHR19 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Westferry Circus Substation (132 kV), about 1.2 km away.
How clean is the power for Digital Realty London LHR19?
The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.
Who operates Digital Realty London LHR19?
Digital Realty.
Data centers near London
- London Hosting Centre 255 m · 9.3 MW
- Cogent London CDC 356 m
- Equinix LD8 - London, Docklands 385 m · 0.6 MW
- Digital Realty London LHR20 651 m · 1.5 MW
- EXA Datacenter London (Citi) 794 m
- Cable & Wireless Data Centre 885 m · 1.3 MW
- Telehouse - London (Docklands South) 1.6 km · 37 MW
- Global Switch London North 1.7 km
More Digital Realty data centers
- Digital Realty CH1 - Chicago United States
- Digital Realty IAD39 United States
- Digital Realty IAD51 United States
- Digital Realty IAD44 United States
- Digital Realty IAD41 United States
- Digital Realty Singapore SIN11 Singapore
- Digital Realty Toronto YYZ11 Canada
- Digital Realty IAD43 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.