Digital Realty OAK (720 2nd St)
Digital Realty OAK (720 2nd St) is an operational data center operated by Digital Realty in Oakland, United States. Our footprint estimate of its power is about 20 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Digital Realty |
| Facility power | 20 MW (range 10 MW to 32 MW) Estimate from building footprint, low confidence. Footprint estimate: about 4,203 m² building outline x 4 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 8,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 6 networks, 1 internet exchanges PeeringDB. |
| Also known as | Digital Realty |
| Address | 720 2nd St |
| Coordinates | 37.79902, -122.28251 |
| Website | digitalrealty.com |
Power and grid
| Nearest high-voltage substation | Oakland C Substation, 115 kV, 100 m away (Pacific Gas and Electric Company) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Embarcadero Substation, 230 kV, 9.8 km away |
| HV substations within 10 km | 15 |
| Utility | Pacific Gas & Electric Co. (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | CISO |
| Nearest gas pipeline | California Gas Transmission Co, intrastate pipeline, 1.5 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 3.3 GW in 33 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 13.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39 °C (2001 to 2025) |
| Cooling degree days | 95 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.14 kWh per m² per day |
| Wind at 50 m | 4.9 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Digital Realty OAK (720 2nd St) use?
We estimate the facility power at about 20 MW. Estimate from building footprint, low confidence.
How close is Digital Realty OAK (720 2nd St) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Oakland C Substation (115 kV), about 100 m away. The local utility is Pacific Gas & Electric Co., in the CISO balancing area.
How clean is the power for Digital Realty OAK (720 2nd St)?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates Digital Realty OAK (720 2nd St)?
Digital Realty.
Data centers near Oakland
- Level(3) Oakland 4.0 km
- Evocative Emeryville (EM1) 5.4 km
- Open Computing Facility 8.1 km
- Lawrence Berkeley NL NERSC Perlmutter 9.2 km · 6.9 MW
- Digital Realty SFO (365 Main) 9.6 km · 7.3 MW
- 274 Brannan Street 9.8 km
- FedConnect San Francisco 9.8 km
- TelePacific 10.0 km
More Digital Realty data centers
- Digital Realty CH1 - Chicago United States
- Digital Realty IAD39 United States
- Digital Realty IAD51 United States
- Digital Realty IAD44 United States
- Digital Realty IAD41 United States
- Digital Realty Singapore SIN11 Singapore
- Digital Realty Toronto YYZ11 Canada
- Digital Realty IAD43 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.