Digital Realty SFO (200 Paul)

Digital Realty SFO (200 Paul) is an operational data center operated by Digital Realty in San Francisco, United States. Our footprint estimate of its power is about 14 MW.

Key facts

StatusOperational
OperatorDigital Realty
Facility power14 MW (range 6.8 MW to 22 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 11,262 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 6,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks45 networks, 2 internet exchanges
PeeringDB.
Also known asSFDC1 - 200 Paul Ave · Wave Data Centers San Francisco · Digital Realty San Francisco SFO10
Address200 Paul Ave
Coordinates37.72341, -122.39792
Websitedigitalrealty.com

Power and grid

Nearest high-voltage substationUnnamed substation, 115 kV, 2.2 km away (Pacific Gas and Electric Company)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationMartin Substation, 230 kV, 2.4 km away
HV substations within 10 km17
UtilityCity & County Of San Francisco (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authorityCISO
Nearest gas pipelineCalifornia Gas Transmission Co, intrastate pipeline, 2.2 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km1.4 GW in 24 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity189 g CO₂ per kWh (California, 2025)
Average of all power made in the area. Ember.
Grid power mixsolar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7%
Industrial power priceUSD 0.241 per kWh (California, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature13.1 °C
NASA POWER, average of 2001 to 2025.
Highest temperature34.4 °C (2001 to 2025)
Cooling degree days20 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.74 kWh per m² per day
Wind at 50 m5.4 m/s average
Water stress todayExtremely High (>80%) (California)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Digital Realty SFO (200 Paul) use?

We estimate the facility power at about 14 MW. Estimate from building footprint, low confidence.

How close is Digital Realty SFO (200 Paul) to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (115 kV), about 2.2 km away. The local utility is City & County Of San Francisco, in the CISO balancing area.

How clean is the power for Digital Realty SFO (200 Paul)?

The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.

Who operates Digital Realty SFO (200 Paul)?

Digital Realty.