Encompass Minneapolis Facility

Encompass Minneapolis Facility is an operational data center operated by Encompass in Lino Lakes, United States. Our footprint estimate of its power is about 8.4 MW.

Key facts

StatusOperational
OperatorEncompass
Facility power8.4 MW (range 4.2 MW to 13 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 7,015 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 3,600 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressHolly Drive 6221, 55038, Lino Lakes
Coordinates45.13216, -93.09562
Websiteencompass.tv/minneapolis

Power and grid

Nearest high-voltage substationUnnamed substation, 115 kV, 7.7 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationKohlman Lake, 345 kV, 11.7 km away
HV substations within 10 km2
UtilityNorthern States Power Co - Minnesota (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityMISO
Nearest gas pipelineNorthern Natural Gas Co, interstate pipeline, 3.9 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km4.1 GW in 91 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity344 g CO₂ per kWh (Minnesota, 2025)
Average of all power made in the area. Ember.
Grid power mixwind 25.1%, coal 23%, nuclear 21.5%, gas 20.7%, solar 5.9%. Clean power: 55.8%
Industrial power priceUSD 0.100 per kWh (Minnesota, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature7 °C
NASA POWER, average of 2001 to 2025.
Highest temperature41.6 °C (2001 to 2025)
Cooling degree days345 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.8 kWh per m² per day
Wind at 50 m6.3 m/s average
Water stress todayMedium - High (20-40%) (Minnesota)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Encompass Minneapolis Facility use?

We estimate the facility power at about 8.4 MW. Estimate from building footprint, low confidence.

How close is Encompass Minneapolis Facility to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (115 kV), about 7.7 km away. The local utility is Northern States Power Co - Minnesota, in the MISO balancing area.

How clean is the power for Encompass Minneapolis Facility?

The grid in Minnesota emits about 344 g CO₂ per kWh (2025). Largest sources: wind 25.1%, coal 23%, nuclear 21.5%.

Who operates Encompass Minneapolis Facility?

Encompass.