Encompass Minneapolis Facility
Encompass Minneapolis Facility is an operational data center operated by Encompass in Lino Lakes, United States. Our footprint estimate of its power is about 8.4 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Encompass |
| Facility power | 8.4 MW (range 4.2 MW to 13 MW) Estimate from building footprint, low confidence. Footprint estimate: about 7,015 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,600 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Holly Drive 6221, 55038, Lino Lakes |
| Coordinates | 45.13216, -93.09562 |
| Website | encompass.tv/minneapolis |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 115 kV, 7.7 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Kohlman Lake, 345 kV, 11.7 km away |
| HV substations within 10 km | 2 |
| Utility | Northern States Power Co - Minnesota (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | MISO |
| Nearest gas pipeline | Northern Natural Gas Co, interstate pipeline, 3.9 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 4.1 GW in 91 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 344 g CO₂ per kWh (Minnesota, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 25.1%, coal 23%, nuclear 21.5%, gas 20.7%, solar 5.9%. Clean power: 55.8% |
| Industrial power price | USD 0.100 per kWh (Minnesota, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41.6 °C (2001 to 2025) |
| Cooling degree days | 345 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.8 kWh per m² per day |
| Wind at 50 m | 6.3 m/s average |
| Water stress today | Medium - High (20-40%) (Minnesota) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Encompass Minneapolis Facility use?
We estimate the facility power at about 8.4 MW. Estimate from building footprint, low confidence.
How close is Encompass Minneapolis Facility to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (115 kV), about 7.7 km away. The local utility is Northern States Power Co - Minnesota, in the MISO balancing area.
How clean is the power for Encompass Minneapolis Facility?
The grid in Minnesota emits about 344 g CO₂ per kWh (2025). Largest sources: wind 25.1%, coal 23%, nuclear 21.5%.
Who operates Encompass Minneapolis Facility?
Encompass.
Data centers near Lino Lakes
- Verus Corportation 13.9 km
- H5 Data Centers Minneapolis 18.2 km · 12 MW
- Implex Minneapolis 19.8 km
- Advanced Operations Center 19.9 km · 2.1 MW
- University of Minnesota Agate 20.7 km · 0.2 MW
- Verizon data center in Minneapolis 21.3 km · 6.8 MW
- Lumen Minneapolis 3 21.4 km · 2.3 MW
- Atomic Data MSP250 21.6 km