Data Center Directory

Equinix DA7 - Dallas

Equinix DA7 - Dallas is an operational data center operated by Equinix in Plano, United States. No power figure is public for this site yet.

Key facts

StatusOperational
OperatorEquinix
Networks6 networks, 3 internet exchanges
PeeringDB.
Also known asT5@Dallas
Address6653 Pinecrest Drive
Coordinates33.06486, -96.81099
Websiteequinix.com/locations/americas-colocation/united-states-colocation/dallas-data-centers/da7

Power and grid

Nearest high-voltage substationUnnamed substation, 345 kV, 600 m away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km25
UtilityGrayson-Collin Elec Coop, INC (cooperative)
Electric retail service territory (HIFLD, US government).
Balancing authorityERCO
Nearest gas pipelineAtmos Pipeline - Texas, intrastate pipeline, 8 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km4.6 GW in 17 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity379 g CO₂ per kWh (Texas, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8%
Industrial power priceUSD 0.072 per kWh (Texas, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature18.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature45.3 °C (2001 to 2025)
Cooling degree days1,559 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.64 kWh per m² per day
Wind at 50 m6.5 m/s average
Water stress todayHigh (40-80%) (Texas)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How close is Equinix DA7 - Dallas to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (345 kV), about 600 m away. The local utility is Grayson-Collin Elec Coop, INC, in the ERCO balancing area.

How clean is the power for Equinix DA7 - Dallas?

The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.

Who operates Equinix DA7 - Dallas?

Equinix.