Equinix HE6 - Helsinki, Sinimäki
Equinix HE6 - Helsinki, Sinimäki is an operational data center operated by Equinix in Espoo, Finland. Our footprint estimate of its power is about 4.6 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 4.6 MW (range 2.3 MW to 7.4 MW) Estimate from building footprint, low confidence. Footprint estimate: about 3,832 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 26 networks, 3 internet exchanges PeeringDB. |
| Also known as | Equinix Data Center HE6 |
| Address | Sinimaentie 12 |
| Coordinates | 60.20303, 24.77786 |
| Website | equinix.com/locations/europe-colocation/finland-colocation/helsinki-data-centers/he6 |
Power and grid
| Nearest high-voltage substation | Hepokorven sähköasema, 400 kV, 6.1 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 6 |
| Power plants within 50 km | 1.5 GW in 10 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 59 g CO₂ per kWh (Finland, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 39.8%, wind 27.4%, hydro 15.1%, bioenergy 12.5%, oil and other fossil 2.3%. Clean power: 96.2% |
| Industrial power price | EUR 0.076 per kWh (Finland, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 6.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 27.9 °C (2001 to 2025) |
| Cooling degree days | 35 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.57 kWh per m² per day |
| Wind at 50 m | 6.3 m/s average |
| Water stress today | Low (<10%) (Finland) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix HE6 - Helsinki, Sinimäki use?
We estimate the facility power at about 4.6 MW. Estimate from building footprint, low confidence.
How close is Equinix HE6 - Helsinki, Sinimäki to the power grid?
The nearest high-voltage substation in OpenStreetMap is Hepokorven sähköasema (400 kV), about 6.1 km away.
How clean is the power for Equinix HE6 - Helsinki, Sinimäki?
The grid in Finland emits about 59 g CO₂ per kWh (2025). Largest sources: nuclear 39.8%, wind 27.4%, hydro 15.1%.
Who operates Equinix HE6 - Helsinki, Sinimäki?
Equinix.
Data centers near Espoo
- Equinix HE7 - Helsinki, Sinimäki 156 m · 11 MW
- atNorth FIN02 377 m
- atNorth FIN03 1.8 km
- Elisa Espoo Säterinportti 2.2 km
- IP-Only Espoo 2.7 km
- Innopoli 2.9 km
- Elisa Espoo Tapiola 2.9 km
- Mediam Helsinki Datacenter 5.4 km
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data