Data Center Directory

Equinix HE7 - Helsinki, Sinimäki

Equinix HE7 - Helsinki, Sinimäki is an operational data center operated by Equinix in Espoo, Finland. Our footprint estimate of its power is about 11 MW.

Key facts

StatusOperational
OperatorEquinix
Facility power11 MW (range 5.6 MW to 18 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 9,314 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 4,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks13 networks, 4 internet exchanges
PeeringDB.
Also known asEquinix Data Center
AddressSinimäentie 8
Coordinates60.20396, 24.77575
Websiteequinix.com/locations/europe-colocation/finland-colocation/helsinki-data-centers/he7

Power and grid

Nearest high-voltage substationHepokorven sähköasema, 400 kV, 6 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km6
Power plants within 50 km1.5 GW in 10 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity59 g CO₂ per kWh (Finland, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 39.8%, wind 27.4%, hydro 15.1%, bioenergy 12.5%, oil and other fossil 2.3%. Clean power: 96.2%
Industrial power priceEUR 0.076 per kWh (Finland, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature6.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature27.9 °C (2001 to 2025)
Cooling degree days35 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.57 kWh per m² per day
Wind at 50 m6.3 m/s average
Water stress todayLow (<10%) (Finland)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Low (<10%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Equinix HE7 - Helsinki, Sinimäki use?

We estimate the facility power at about 11 MW. Estimate from building footprint, low confidence.

How close is Equinix HE7 - Helsinki, Sinimäki to the power grid?

The nearest high-voltage substation in OpenStreetMap is Hepokorven sähköasema (400 kV), about 6 km away.

How clean is the power for Equinix HE7 - Helsinki, Sinimäki?

The grid in Finland emits about 59 g CO₂ per kWh (2025). Largest sources: nuclear 39.8%, wind 27.4%, hydro 15.1%.

Who operates Equinix HE7 - Helsinki, Sinimäki?

Equinix.

Data centers near Espoo

More Equinix data centers

Sources

Correct this page or get the data