Equinix MA3 - Manchester, Joule House
Equinix MA3 - Manchester, Joule House is an operational data center operated by Equinix in Manchester, United Kingdom. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Networks | 51 networks, 2 internet exchanges PeeringDB. |
| Address | 76 Trafford Park Road, Trafford Park |
| Coordinates | 53.46867, -2.31042 |
| Website | equinix.com/locations/united-kingdom-colocation/manchester-data-centers/ma3 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 132 kV, 1.1 km away (Electricity North West) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | South Manchester Substation, 275 kV, 5.8 km away |
| HV substations within 10 km | 19 |
| Power plants within 50 km | 3.5 GW in 85 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 218 g CO₂ per kWh (United Kingdom, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2% |
Climate and water
| Average temperature | 9.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 28 °C (2001 to 2025) |
| Cooling degree days | 7 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.75 kWh per m² per day |
| Wind at 50 m | 7.2 m/s average |
| Water stress today | Low - Medium (10-20%) (England) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Equinix MA3 - Manchester, Joule House to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (132 kV), about 1.1 km away.
How clean is the power for Equinix MA3 - Manchester, Joule House?
The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.
Who operates Equinix MA3 - Manchester, Joule House?
Equinix.
Data centers near Manchester
- AtlasEdge DC Manchester MAN001 925 m
- LDeX2 1.1 km
- Joule House 1.1 km · 4.5 MW
- Pulsant Manchester NW-1 1.2 km
- ANS - MAN5 1.2 km
- ANS - MAN4 1.4 km
- Equinix MA5 - Manchester 4.0 km
- Volta Manchester 4.2 km · 3.9 MW
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.