Data Center Directory

Equinix ML5 - Milan

Equinix ML5 - Milan is an operational data center operated by Equinix in 5 Settimo Milanese, Italy. Our footprint estimate of its power is about 8.5 MW.

Key facts

StatusOperational
OperatorEquinix
Facility power8.5 MW (range 4.3 MW to 14 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 7,089 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 3,600 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks25 networks, 1 internet exchanges
PeeringDB.
Also known asEquinix ML7x · Equinix ML5
AddressVia Marisa Bellisario
Coordinates45.47539, 9.03836
Websiteequinix.com/data-centers/europe-colocation/italy-colocation/milan-data-centers/ml5

Power and grid

Nearest high-voltage substationUT Italtel, 132 kV, 300 m away (Italtel)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationBaggio, 380 kV, 1.8 km away
HV substations within 10 km37
Power plants within 50 km5.6 GW in 19 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity285 g CO₂ per kWh (Italy, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 47.4%, solar 16.8%, hydro 15.7%, wind 8.1%, bioenergy 5.9%. Clean power: 48.7%
Industrial power priceEUR 0.173 per kWh (Italy, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature13.2 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.2 °C (2001 to 2025)
Cooling degree days482 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.78 kWh per m² per day
Wind at 50 m3 m/s average
Water stress todayHigh (40-80%) (Italy)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Equinix ML5 - Milan use?

We estimate the facility power at about 8.5 MW. Estimate from building footprint, low confidence.

How close is Equinix ML5 - Milan to the power grid?

The nearest high-voltage substation in OpenStreetMap is UT Italtel (132 kV), about 300 m away.

How clean is the power for Equinix ML5 - Milan?

The grid in Italy emits about 285 g CO₂ per kWh (2025). Largest sources: gas 47.4%, solar 16.8%, hydro 15.7%.

Who operates Equinix ML5 - Milan?

Equinix.