Equinix PA6 - Paris, Condorcet
Equinix PA6 - Paris, Condorcet is an operational data center operated by Equinix in Paris, France. Our footprint estimate of its power is about 9.2 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 9.2 MW (range 4.6 MW to 15 MW) Estimate from building footprint, low confidence. Footprint estimate: about 7,629 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,900 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 66 networks, 4 internet exchanges PeeringDB. |
| Also known as | Equinix PA6 |
| Address | 10 Rue Waldeck Rochet, Batiment 520 |
| Coordinates | 48.91025, 2.36825 |
| Website | equinix.com/locations/france-colocation/paris-data-centers/pa6 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 225 kV, 100 m away (Enedis) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 67 |
| Power plants within 50 km | 2.2 GW in 53 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.6 °C (2001 to 2025) |
| Cooling degree days | 130 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.19 kWh per m² per day |
| Wind at 50 m | 6.3 m/s average |
| Water stress today | Low - Medium (10-20%) (France) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix PA6 - Paris, Condorcet use?
We estimate the facility power at about 9.2 MW. Estimate from building footprint, low confidence.
How close is Equinix PA6 - Paris, Condorcet to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (225 kV), about 100 m away.
How clean is the power for Equinix PA6 - Paris, Condorcet?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates Equinix PA6 - Paris, Condorcet?
Equinix.
Data centers near Paris
- MCI/Verizon Paris St Denis 390 m
- nLighten Paris PAR2 393 m · 2.4 MW
- Digital Realty Paris PAR2 434 m · 15 MW
- Digital Realty Paris PAR3 656 m · 4 MW
- Equinix PA5 - Paris, Victor Hugo 691 m · 3 MW
- Digital Realty Paris PAR5 697 m · 2.6 MW
- Digital Realty Paris PAR1 913 m
- Orange - Aubervilliers 1.9 km · 15 MW
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.