Equinix SP4 - São Paulo
Equinix SP4 - São Paulo is an operational data center operated by Equinix in Barueri, Brazil. Our footprint estimate of its power is about 1.9 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 1.9 MW (range 0.8 MW to 4.8 MW) Estimate from building footprint, low confidence. Footprint estimate: about 15,918 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 810 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 606 networks, 6 internet exchanges PeeringDB. |
| Also known as | Equinix |
| Address | Av. Ceci, 1900 - Res. Tambore, Tamboré |
| Coordinates | -23.49759, -46.81458 |
| Website | equinix.com/locations/americas-colocation/brazil-colocation/sao-paulo-data-centers/sp4 |
Power and grid
| Nearest high-voltage substation | Subestação Anhangüera, 345 kV, 4.8 km away (CTEEP) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 3 |
| Power plants within 50 km | 669 MW in 6 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 109 g CO₂ per kWh (Brazil, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 52.1%, wind 15.2%, solar 11.5%, bioenergy 8.1%, gas 7.8%. Clean power: 88.9% |
Climate and water
| Average temperature | 19.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38.6 °C (2001 to 2025) |
| Cooling degree days | 955 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.53 kWh per m² per day |
| Wind at 50 m | 5 m/s average |
| Water stress today | Low - Medium (10-20%) (Brazil) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix SP4 - São Paulo use?
We estimate the facility power at about 1.9 MW. Estimate from building footprint, low confidence.
How close is Equinix SP4 - São Paulo to the power grid?
The nearest high-voltage substation in OpenStreetMap is Subestação Anhangüera (345 kV), about 4.8 km away.
How clean is the power for Equinix SP4 - São Paulo?
The grid in Brazil emits about 109 g CO₂ per kWh (2025). Largest sources: hydro 52.1%, wind 15.2%, solar 11.5%.
Who operates Equinix SP4 - São Paulo?
Equinix.
Data centers near Barueri
- B-BRIX - SPO1 54 m
- Scala Data Center 104 m · 56 MW
- Scala Data Centers SGRUTB04 169 m
- Scala Data Centers SGRUTB01 443 m
- Scala Data Centers SGRUTB03 625 m · 17 MW
- Equinix SP4 Terremark 662 m
- Equinix SP2 - São Paulo 1.4 km
- Omid Solutions Barueri 2.2 km
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States