EXA Edge DC Garching
EXA Edge DC Garching is an operational data center operated by EXA Infrastructure in Garching bei München, Germany. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | EXA Infrastructure |
| Networks | 1 networks PeeringDB. |
| Address | Robert-Bosch-Str. 12, 85748 Garching bei München |
| Coordinates | 48.25558, 11.61222 |
| Website | exainfra.net |
Power and grid
| Nearest high-voltage substation | Umspannwerk Hochbrück, 110 kV, 1.2 km away (Bayernwerk) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Hauptumspannwerk Föhring, 380 kV, 8.8 km away |
| HV substations within 10 km | 12 |
| Power plants within 50 km | 2.8 GW in 61 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 8.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 32.6 °C (2001 to 2025) |
| Cooling degree days | 109 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.25 kWh per m² per day |
| Wind at 50 m | 5.5 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is EXA Edge DC Garching to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Hochbrück (110 kV), about 1.2 km away.
How clean is the power for EXA Edge DC Garching?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates EXA Edge DC Garching?
EXA Infrastructure.
Data centers near Garching bei München
- nLighten Munich MUC1 74 m
- LRZ SuperMUC-NG 4.1 km · 19 MW
- Max-Planck-Gesellschaft Raven 4.5 km · 0.7 MW
- Rechenzentrum Garching 4.6 km · 1.6 MW
- NTT Munich 2 Data Center (MUC2) 5.0 km
- Data center in Unterföhring 6.3 km · 2.3 MW
- EMC Home of Data MUC I/II - MuCon-X 6.8 km
- Arelion Munich MCN 7.7 km
More EXA Infrastructure data centers
- EXA Edge DC Frankfurt1 Germany
- EXA Infrastructure Ireland
- EXA Datacenter Bracknell United Kingdom
- EXA Edge DC Marseille France
- EXA Edge DC Strasbourg France
- EXA Edge DC Bordeaux France
- EXA CLS Lynn United States
- EXA Datacenter London (Citi) United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.