freenet Duesseldorf
freenet Duesseldorf is an operational data center operated by TERRA CLOUD Duesseldorf in Düsseldorf, Germany. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | TERRA CLOUD Duesseldorf |
| Networks | 1 networks PeeringDB. |
| Address | Willsttätterstrasse 13 |
| Coordinates | 51.23996, 6.71571 |
| Website | terracloud.de |
Power and grid
| Nearest high-voltage substation | Station Büderich, 110 kV, 800 m away (Westnetz) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Station Osterath, 220 kV, 6.7 km away |
| HV substations within 10 km | 18 |
| Power plants within 50 km | 14 GW in 62 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.6 °C (2001 to 2025) |
| Cooling degree days | 131 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.96 kWh per m² per day |
| Wind at 50 m | 6.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is freenet Duesseldorf to the power grid?
The nearest high-voltage substation in OpenStreetMap is Station Büderich (110 kV), about 800 m away.
How clean is the power for freenet Duesseldorf?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates freenet Duesseldorf?
TERRA CLOUD Duesseldorf.
Data centers near Düsseldorf
- Penta Infra Dusseldorf DUS01 1.6 km
- euNetworks Duesseldorf - site closed 5.4 km
- KPN DSSD2 6.1 km
- Equinix DU1 - Dusseldorf 6.8 km · 1.2 MW
- WIIT Datacenter DUS1, DUS2, DUS3, DUS4, DUS6, DUS7 7.7 km
- Lumen Duesseldorf 11.9 km
- Arelion Dusseldorf DDF/B 12.0 km
- NorthC Duesseldorf 12.0 km