euNetworks Duesseldorf - site closed
euNetworks Duesseldorf - site closed is an operational data center operated by euNetworks in Düsseldorf, Germany. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | euNetworks |
| Address | Leopoldstrasse 16 |
| Coordinates | 51.22651, 6.79022 |
| Website | euNetworks.com |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 110 kV, 1.6 km away (Stadtwerke Düsseldorf) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Station Eller, 220 kV, 4.6 km away |
| HV substations within 10 km | 20 |
| Power plants within 50 km | 15 GW in 63 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.2 °C (2001 to 2025) |
| Cooling degree days | 142 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.96 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is euNetworks Duesseldorf - site closed to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (110 kV), about 1.6 km away.
How clean is the power for euNetworks Duesseldorf - site closed?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates euNetworks Duesseldorf - site closed?
euNetworks.
Data centers near Düsseldorf
- Equinix DU1 - Dusseldorf 1.4 km · 1.2 MW
- KPN DSSD2 3.6 km
- WIIT Datacenter DUS1, DUS2, DUS3, DUS4, DUS6, DUS7 4.9 km
- freenet Duesseldorf 5.4 km
- Lumen Duesseldorf 6.7 km
- Arelion Dusseldorf DDF/B 6.8 km
- NorthC Duesseldorf 6.9 km
- Penta Infra Dusseldorf DUS01 7.0 km
More euNetworks data centers
- euNetworks Colocation Hamburg Germany
- euNetworks Amsterdam Netherlands
- euNetworks (Global Voice) Ireland
- euNetworks Colocation Karlsruhe Germany
- euNetworks Colocation Dortmund Germany
- euNetworks Colocation Bielefeld Germany
- euNetworks Colocation Bremen Germany
- euNetworks Colocation Dresden Germany
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.