GlobalConnect Taastrup 1 (CPH1)

GlobalConnect Taastrup 1 (CPH1) is an operational data center operated by GlobalConnect in Taastrup, Denmark. Our footprint estimate of its power is about 5.4 MW.

Key facts

StatusOperational
OperatorGlobalConnect
Facility power5.4 MW (range 2.7 MW to 8.6 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 4,474 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 2,300 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks57 networks, 7 internet exchanges
PeeringDB.
AddressHørskætten 3-5 and 12, 2630 Taastrup
Coordinates55.66200, 12.30146
Websiteglobalconnect.dk/tjenester/datacenter

Power and grid

Nearest high-voltage substationVejleå transformerstation, 132 kV, 1.1 km away (Radius Elnet;Energinet)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substation400/132 kV Ishøj, 400 kV, 3.5 km away
HV substations within 10 km13
Power plants within 50 km2.2 GW in 18 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity120 g CO₂ per kWh (Denmark, 2025)
Average of all power made in the area. Ember.
Grid power mixwind 56.9%, bioenergy 21.4%, solar 12.8%, oil and other fossil 4.9%, coal 2.5%. Clean power: 91.2%
Industrial power priceEUR 0.118 per kWh (Denmark, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature9 °C
NASA POWER, average of 2001 to 2025.
Highest temperature30 °C (2001 to 2025)
Cooling degree days44 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.91 kWh per m² per day
Wind at 50 m7.6 m/s average
Water stress todayLow (<10%) (Denmark)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Low (<10%)
Business-as-usual scenario.

Satellite view

Questions

How much power does GlobalConnect Taastrup 1 (CPH1) use?

We estimate the facility power at about 5.4 MW. Estimate from building footprint, low confidence.

How close is GlobalConnect Taastrup 1 (CPH1) to the power grid?

The nearest high-voltage substation in OpenStreetMap is Vejleå transformerstation (132 kV), about 1.1 km away.

How clean is the power for GlobalConnect Taastrup 1 (CPH1)?

The grid in Denmark emits about 120 g CO₂ per kWh (2025). Largest sources: wind 56.9%, bioenergy 21.4%, solar 12.8%.