GlobalConnect Taastrup 1 (CPH1)
GlobalConnect Taastrup 1 (CPH1) is an operational data center operated by GlobalConnect in Taastrup, Denmark. Our footprint estimate of its power is about 5.4 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | GlobalConnect |
| Facility power | 5.4 MW (range 2.7 MW to 8.6 MW) Estimate from building footprint, low confidence. Footprint estimate: about 4,474 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,300 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 57 networks, 7 internet exchanges PeeringDB. |
| Address | Hørskætten 3-5 and 12, 2630 Taastrup |
| Coordinates | 55.66200, 12.30146 |
| Website | globalconnect.dk/tjenester/datacenter |
Power and grid
| Nearest high-voltage substation | Vejleå transformerstation, 132 kV, 1.1 km away (Radius Elnet;Energinet) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | 400/132 kV Ishøj, 400 kV, 3.5 km away |
| HV substations within 10 km | 13 |
| Power plants within 50 km | 2.2 GW in 18 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 120 g CO₂ per kWh (Denmark, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 56.9%, bioenergy 21.4%, solar 12.8%, oil and other fossil 4.9%, coal 2.5%. Clean power: 91.2% |
| Industrial power price | EUR 0.118 per kWh (Denmark, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 30 °C (2001 to 2025) |
| Cooling degree days | 44 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.91 kWh per m² per day |
| Wind at 50 m | 7.6 m/s average |
| Water stress today | Low (<10%) (Denmark) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does GlobalConnect Taastrup 1 (CPH1) use?
We estimate the facility power at about 5.4 MW. Estimate from building footprint, low confidence.
How close is GlobalConnect Taastrup 1 (CPH1) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Vejleå transformerstation (132 kV), about 1.1 km away.
How clean is the power for GlobalConnect Taastrup 1 (CPH1)?
The grid in Denmark emits about 120 g CO₂ per kWh (2025). Largest sources: wind 56.9%, bioenergy 21.4%, solar 12.8%.
Who operates GlobalConnect Taastrup 1 (CPH1)?
GlobalConnect.
Data centers near Taastrup
- GlobalConnect Taastrup 2 361 m
- CPH07 3.3 km · 21 MW
- Adeo Datacenter 4.2 km · 4.1 MW
- GlobalConnect Albertslund (CPH3) 4.2 km
- Norlys Telehouse Copenhagen 4.8 km
- Penta Infra Copenhagen CPH01 6.3 km
- Cibicom Datacenter CPH West 7.3 km
- Aeven data center in Rødovre 8.0 km · 2 MW
More GlobalConnect data centers
- GlobalConnect Glostrup Denmark
- GC-FAB7 Stavanger Norway
- GlobalConnect Albertslund (CPH3) Denmark
- GlobalConnect Gothenburg Sweden
- GlobalConnect Hamburg (HAM1) Germany
- GlobalConnect Hørning 2 Denmark
- GlobalConnect Järfälla Sweden
- GlobalConnect Kolding Denmark
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.