Kapsch BusinessCom earthDATAsafe
Kapsch BusinessCom earthDATAsafe is an operational data center operated by Kapsch BusinessCom in Pötschach, Austria. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Kapsch BusinessCom |
| Networks | 4 networks PeeringDB. |
| Also known as | earthDATAsafe |
| Address | Höhkogel 1 |
| Coordinates | 47.44914, 15.33820 |
| Website | kapsch.net/kbc/SolutionService/DigitalFacilitySolutions |
Power and grid
| Nearest high-voltage substation | Umspannwerk Kapfenberg, 110 kV, 3.3 km away (Energie Steiermark) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Hessenberg, 220 kV, 24.6 km away |
| HV substations within 10 km | 5 |
| Power plants within 50 km | 388 MW in 18 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 117 g CO₂ per kWh (Austria, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 51.9%, solar 14.1%, gas 11.9%, wind 11.4%, bioenergy 6.3%. Clean power: 83.6% |
| Industrial power price | EUR 0.150 per kWh (Austria, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 7.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34 °C (2001 to 2025) |
| Cooling degree days | 68 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.24 kWh per m² per day |
| Wind at 50 m | 4.1 m/s average |
| Water stress today | Low (<10%) (Austria) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Kapsch BusinessCom earthDATAsafe to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Kapfenberg (110 kV), about 3.3 km away.
How clean is the power for Kapsch BusinessCom earthDATAsafe?
The grid in Austria emits about 117 g CO₂ per kWh (2025). Largest sources: hydro 51.9%, solar 14.1%, gas 11.9%.
Who operates Kapsch BusinessCom earthDATAsafe?
Kapsch BusinessCom.
Data centers near Pötschach
- Telekom-Tower 43.1 km · 6.6 MW
- T-Mobile Rechenzentrum Graz 45.9 km · 3.5 MW
- XINON Graz 46.1 km
- Raiffeisen Rechenzentrum (Raaba) 48.2 km
- Gradbišče ARNES 100.3 km · 2.5 MW
- EuroHPC Vega 101.3 km · 0.2 MW
- Posta Slovenije d.o.o. 101.7 km
- Data center in Prevalje 103.8 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.