Raiffeisen Rechenzentrum (Raaba)
Raiffeisen Rechenzentrum (Raaba) is an operational data center operated by Raiffeisen Rechenzentrum in Raaba-Grambach, Austria. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Raiffeisen Rechenzentrum |
| Networks | 5 networks PeeringDB. |
| Address | Raiffeisen-Platz 1 |
| Coordinates | 47.02816, 15.49169 |
| Website | rrz.co.at/services/housing |
Power and grid
| Nearest high-voltage substation | Umspannwerk Grambach, 110 kV, 1.3 km away (Energie Steiermark) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Mellach, 380 kV, 13.1 km away |
| HV substations within 10 km | 12 |
| Power plants within 50 km | 1.3 GW in 28 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 117 g CO₂ per kWh (Austria, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 51.9%, solar 14.1%, gas 11.9%, wind 11.4%, bioenergy 6.3%. Clean power: 83.6% |
| Industrial power price | EUR 0.150 per kWh (Austria, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39 °C (2001 to 2025) |
| Cooling degree days | 267 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.24 kWh per m² per day |
| Wind at 50 m | 4.1 m/s average |
| Water stress today | Low (<10%) (Austria) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Raiffeisen Rechenzentrum (Raaba) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Grambach (110 kV), about 1.3 km away.
How clean is the power for Raiffeisen Rechenzentrum (Raaba)?
The grid in Austria emits about 117 g CO₂ per kWh (2025). Largest sources: hydro 51.9%, solar 14.1%, gas 11.9%.
Who operates Raiffeisen Rechenzentrum (Raaba)?
Raiffeisen Rechenzentrum.
Data centers near Raaba-Grambach
- XINON Graz 2.6 km
- T-Mobile Rechenzentrum Graz 5.2 km · 3.5 MW
- Telekom-Tower 6.3 km · 6.6 MW
- Kapsch BusinessCom earthDATAsafe 48.2 km
- Gradbišče ARNES 52.2 km · 2.5 MW
- EuroHPC Vega 53.1 km · 0.2 MW
- Posta Slovenije d.o.o. 53.5 km
- Data center in Prevalje 67.5 km