Keppel Data Centres | Keppel DC Singapore 2

Keppel Data Centres | Keppel DC Singapore 2 is an operational data center operated by Keppel Data Centres in Singapore, Singapore. Our footprint estimate of its power is about 1.8 MW.

Key facts

StatusOperational
OperatorKeppel Data Centres
Facility power1.8 MW (range 0.7 MW to 4.6 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 15,232 m² site outline x 0.12 kW per m² of land.
GPU capacity if all AIabout 770 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asKeppel Data Centres | Keppel DC Singapore 3 · Keppel DC Singapore 3 · Keppel DC Singapore 2 · Amazon SIN3
Address25 Tampines Street 92, Singapore 528877
Coordinates1.34081, 103.94412
Websitekeppeldatacentres.com

Power and grid

Nearest high-voltage substationTampines Wafer Substation 230kV, 230 kV, 3.4 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km3
Power plants within 50 km19 GW in 38 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity497 g CO₂ per kWh (Singapore, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 91.1%, bioenergy 2.8%, solar 2.7%, oil and other fossil 2.5%, coal 0.9%. Clean power: 5.5%

Climate and water

Average temperature27.1 °C
NASA POWER, average of 2001 to 2025.
Highest temperature33.9 °C (2001 to 2025)
Cooling degree days3,296 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.82 kWh per m² per day
Wind at 50 m4 m/s average
Water stress todayNoData (Singapore)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.

Satellite view

Questions

How much power does Keppel Data Centres | Keppel DC Singapore 2 use?

We estimate the facility power at about 1.8 MW. Estimate from building footprint, low confidence.

How close is Keppel Data Centres | Keppel DC Singapore 2 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Tampines Wafer Substation 230kV (230 kV), about 3.4 km away.

How clean is the power for Keppel Data Centres | Keppel DC Singapore 2?

The grid in Singapore emits about 497 g CO₂ per kWh (2025). Largest sources: gas 91.1%, bioenergy 2.8%, solar 2.7%.