Keppel Data Centres | iSeek Data Centre
Keppel Data Centres | iSeek Data Centre is an operational data center operated by Keppel Data Centres in Brisbane, Australia. Our footprint estimate of its power is about 4.1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Keppel Data Centres |
| Facility power | 4.1 MW (range 2 MW to 6.5 MW) Estimate from building footprint, low confidence. Footprint estimate: about 3,377 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 3 networks, 1 internet exchanges PeeringDB. |
| Also known as | DigiCo Brisbane BNE2 (iseek LDR2) · DigiCo BNE1 |
| Address | 2 Cycas Lane, Brisbane Airport |
| Coordinates | -27.41567, 153.09125 |
| Website | keppeldatacentres.com |
Power and grid
| Nearest high-voltage substation | Meeandah substation, 110 kV, 2.7 km away (Energex) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Murarrie Substation, 275 kV, 4.1 km away |
| HV substations within 10 km | 17 |
| Power plants within 50 km | 960 MW in 5 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 518 g CO₂ per kWh (Australia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 42.9%, solar 20.4%, gas 15.5%, wind 13.8%, hydro 4.4%. Clean power: 39.8% |
Climate and water
| Average temperature | 21.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.6 °C (2001 to 2025) |
| Cooling degree days | 1,318 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.15 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Low - Medium (10-20%) (Queensland) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Keppel Data Centres | iSeek Data Centre use?
We estimate the facility power at about 4.1 MW. Estimate from building footprint, low confidence.
How close is Keppel Data Centres | iSeek Data Centre to the power grid?
The nearest high-voltage substation in OpenStreetMap is Meeandah substation (110 kV), about 2.7 km away.
How clean is the power for Keppel Data Centres | iSeek Data Centre?
The grid in Australia emits about 518 g CO₂ per kWh (2025). Largest sources: coal 42.9%, solar 20.4%, gas 15.5%.
Who operates Keppel Data Centres | iSeek Data Centre?
Keppel Data Centres.
Data centers near Brisbane
- DigiCo BNE2 138 m · 12 MW
- NEXTDC B2 7.1 km
- Equinix BR1 - Brisbane (formerly Metronode Brisbane 1) 7.2 km
- Over the Wire - 360 St Pauls 7.3 km
- 5GN Brisbane Data Centre (BDC) 7.4 km
- AAPT Fortitude Valley 7.7 km
- Christie Systems DC1 8.2 km
- NEXTDC B1 8.2 km
More Keppel Data Centres data centers
- Keppel Data Centres | Keppel DC Singapore 5 Singapore
- Keppel Data Centres | Keppel DC Sydney 1 Australia
- Keppel Genting Lane Campus Singapore
- Keppel Data Centres | Keppel DC Singapore 2 Singapore
- Keppel Data Centres | Keppel DC Singapore 4 Singapore
- Keppel Data Centres | Keppel DC Singapore 1 Singapore
- Keppel Data Centres | Basis Bay Data Centre Malaysia
- Keppel Data Centres | Cardiff Data Centre United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.